Injection system
Disassembly, cleaning, assembly and adjustment of injection nozzles
07.1—137 Disassembly, cleaning, assembly and adjustment of injection nozzles Job no. of flat rates or standard texts and flat rates data 07-6750 or 6752. Testing data, injection nozzles Bosch designation Injection pressure…
Checking injection nozzles
07.1—135 Checking injection nozzles Job no. of flat rates or standard texts and flat rates data 07—6712. Test values injection nozzles Bosch designation Injection pressure in bar positive for new injection nozzles…
Adjusting injection timing (begin of delivery) (position indicator RIV method) following checkup
07.1—116 Adjusting injection timing (begin of delivery) (position indicator RIV method) following checkup Job no. of flat rates or standard texts and flat rates data 07—8300. Note Check begin…
Adjusting injection timing (begin of delivery) (high pressure method) following checkup
07.1-115 Adjusting injection timing (begin of delivery) (high pressure method) following checkup Job no. of flat rates or standard texts and flat rates data 07—8300. Special tool Socket element 13 mm, 3/8″…
Adjusting injection timing (begin of delivery) with digital tester (RIV method) following checkup
07.1-114 Adjusting injection timing (begin of delivery) with digital tester (RIV method) following checkup Job no. of flat rates or standard texts and flat rates data 07—8300. Testing and adjusting value Rl-adjusting value…
Checking injection timing (begin of delivery) (position indicator RIV method)
07.1-111 Checking injection timing (begin of delivery) (position indicator RIV method) Job no. of flat rates or standard texts and flat rates data 07—8240. Testing and adjusting value Rl-test value (indirect injection…
Checking injection timing (begin of delivery) (flow pressure method)
07.1—110 Checking injection timing (begin of delivery) (flow pressure method) Job no. of flat rates or standard texts and flat rates data 07—8228 or 8231. Test value Start of delivery before TDC in…
Checking injection timing (begin of delivery) (high pressure method)
07.1—109 Checking injection timing (begin of delivery) (high pressure method) Job no. of flat rates or standard texts and flat rates data 07—8234. Test values Injection timing (begin of delivery) before TDC in…
Checking injection timing (begin of delivery) with digital tester (RIV method)
07.1—108 Checking injection timing (begin of delivery) with digital tester (RIV method) Job no. of flat rates or standard texts and flat rates data 07—8244. Testing and adjusting value Rl-test value (indirect…
Checking maximum speed at no-load
07.1—105 Checking maximum speed at no-load Test value Maximum speed at no-load (end of control range) 4900-5200/min Conventional tester Digital tester e.g. Bosch, MOT 001.03 Checking 1 …