Adjusting injection timing (begin of delivery) with digital tester (RIV method) following checkup
|
|||||
07.1-114 Adjusting injection timing (begin of delivery) with digital tester (RIV method) following checkup
|
|||||
|
|||||
Job no. of flat rates or standard texts and flat rates data 07—8300.
|
|||||
|
|||||
Testing and adjusting value
Rl-adjusting value (indirect injection timing)
Tightening torque
Closing plug on regulator (measuring point)
Special tool
Adjusting device
|
-15° after TDC
Nm 30-35
617 589 07 21 00
|
||||
|
|||||
Note
|
|||||
|
|||||
Prior to adjustment, check ignition timing (07.1 — 108).
|
|||||
|
|||||
Adjusting
|
|||||
1 Mount holding bracket (01) on injection pump housing.
|
|||||
|
|||||
2 Place adjusting device (02) on cylinder head screws and holding fork (arrows).
|
|||||
|
|||||
07.1.8-114/1 F3
|
|||||
|
|||||
|
|||
3 Loosen nuts on injection pump flange as well as screws (3) on supporting bracket (4).
|
|||
3 Screw
4 Supporting bracket
|
|||
|
|||
4 Adjust begin of delivery at idle speed by turning hex. head screw (arrow).
Rl-value: -15° after TDC.
|
|||
Swivelling direction of injection pump
Toward engine = delivery begins earlier Away from engine = delivery begins later
|
|||
5 Tighten nuts and screw for injection pump. Check preset value.
6 Stop engine.
7 Disconnect tester and Rl-transmitter. Screw in closing plug (2) and tighten to 30—35 Nm.
8 Run engine and check for leaks.
9 Check oil level and correct, if required.
|
|||
|
|||
07.1.8-114/2 F 3
|
|||
|
|||