Replacement of vacuum control unit at injection pump
|
|||
07.1-220 Replacement of vacuum control unit at injection pump
Job no. of flat rates or standard texts and flat rates data 07-8621.
|
|||
|
|||
Removal
|
![]() |
||
1 Unscrew vacuum control valve on injection pump.
2 Remove vacuum control unit after loosening 4 fastening screws.
|
|||
|
|||
Installation
|
|||
|
|||
3 Bolt vacuum control unit to governor cover, using 2 new gaskets (1).
Make sure that connecting rod of vacuum control unit latches onto control rod.
|
![]() |
||
|
|||
1 Gasket
2 Steel ring
|
107-12972/1
|
||
|
|||
07.1.8-220/1 F3
|
|||
|
|||