Removal and installation of air cleaner
|
|||
09-400 Removal and installation of air cleaner
|
|||
|
|||
Note
|
|||
The air cleaner top is provided with a recess (arrow) for adjusting idle speed mixture.
As a result, the air cleaner need no longer be removed for adjusting idle speed mixture.
|
|||
|
|||
On air cleaner 2nd version the air intake proceeds directly at air cleaner, the connecting hose is no longer required.
|
|||
|
|||
The connection for the decel shutoff valve is at air cleaner lower half.
Air intake is by way of a rubber scoop (arrow) at clean air side.
|
|||
|
|||
09.2 Mb—400/1 F 2
|
|||
|
|||
|
|||
Removal
|
|||
1 Unscrew both fastening nuts on vibration dampers.
2 Remove air cleaner, while pulling off contour hose for crankcase breather.
|
|||
|
|||
Installation
|
|||
3 Remove air cleaner cover.
4 Mount air cleaner. Pay attention to correct seat of sealing ring (arrow) between air flow sensor and air cleaner.
5 Mount air cleaner cover.
|
|||
|
|||
09.2 llb-400/2 F 2
|
|||
|
|||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Air cleaner
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Holder
Air cleaner lower half 1st version
Hose clamp
Intake hose
Intake scoop
Air cleaner 2nd version
Connection for decel shutoff
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09.2 llb-400/3 F2
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||