Ignition system,  M110

Checking and adjusting closing angle (dwell angle) and firing point

 

 

07.5—500 Checking and adjusting closing angle (dwell angle) and firing point

 

Closing angle (dwell angle)

 

Normal coil ignition

 

Closing angle (dwell angle) Testing and adjusting value at idle1)
Change between idle and 3000/min

 

39-42
max. ± 3

 

‘) When installing new breaker points, adjust closing angle (dwell angle) to 42 ± 1°.
Transistorized ignition system (T
Identification: blue ignition coil, two pre-resistors and transistorized switchgear.

 

Closing angle (dwell angle) Testing and adjusting value at idle2)
Change between idle and 3000/min

 

30-40
max. ± 3

 

2) When installing new and when adjusting used breaker points, adjust closing angle (dwell angle) to 34 ± 1°.

 

Firing point

 

Ignition distributor Bosch no.
Adjusting value of firing point
Test value Ignition adjustment without vacuum
4500/min
Vacuum adjustment after
Installation value of ignition distributor at starting speed
without vacuum
with vacuum at idle
1500/min
3000/min
“retard” at idle
“advance” at 4500/min (total)

 

1976

 

0 231 309 001
TDC
11-17′
26-30c
26-30c
4-6c
8-12° (34-42
5° before TDC

 

J) 1976

 

0 231 311 001
7° before TDC
10-16c
26-33c
29-35c
7° before TDC

 

1973/74

 

0 231 310 002
4° after TDC
13-17°         31-35°         37-41°         9-13
7° before TDC

 

(USA) 1975/76

 

0 231 311 001
7° before TDC
10-16° 26-33° 29-35
7° before TDC

 

Special tools

 

Digital tester
m110 - 0553-1.jpg
001 589 54 21 00

 

07.5.2 lb-500/1

 

 

 

Connecting cable
m110 - 0554-1.jpg
000 589 04 90 00

 

Intermediate plug (adaptor)
m110 - 0554-2.jpg
000 589 72 63 00

 

Trigger
m110 - 0554-3.jpg
000 589 71 63 00

 

Conventional tools

 

Revolution counter, stroboscope, closing angle (dwell angle) measuring instrument

 

Checking and adjusting closing angle (dwell angle)
m110 - 0554-4.jpg
1    Measure closing angle (dwell angle) at idle speed.
2    Measure closing angle (dwell angle) change between idle speed and 3000/min, max. change ± 3°
3   Adjust closing angle (dwell angle), if required or replace breaker points (07.5—505).
With used breaker points, the closing angle (dwell angle) can be adjusted only with transistorized ignition.
Large dwell angle — small point spacing Small dwell angle — large point spacing

 

Checking and adjusting firing point

 

4 Measure firing point with stroboscope or digital tester at specified speed with or without vacuum.

 

07.5.2 lb-500/2

 

 

 

5    Loosen ignition distributor and set adjusting value of firing point by turning ignition distributor.
Screw down ignition distributor and check firing point.
6   Check centrifugal and vacuum adjustment of ig­nition distributor. For this purpose”, run through specified test values with or without vacuum adjust­ment.
m110 - 0555-1.jpg

 

07.5.2 lb-500/3