Subsequent installation of bypass bores of stage II
07.2—176 Subsequent installation of bypass bores of stage II
Note
To prevent bypass faults (stage jump) from stage I to stage II, the bypass bores (arrow) are located 8 mm deeper under air valve starting January 1973 or starting carburetor cover code number “04”, respectively. Subsequent installation is generally possible.
Scope
1 Remove carburetor cover, remove air valves of stage 11.
2 Close former bypass bores by riveting with aluminum plugs of 2 mm dia. and, in similar alignment underneath, 8 mm above carburetor cover parting surface, drill a new bypass bore 2 mm dia. for each stage.
Carburetor cover code number
07.2.2 la—176/1
3 Blow through riser pipes (158) for stage II, install air valves, while paying attention to easy operation of valves.