Checking, adjusting zero position of air flow sensor plate
WIS 07.3-1612
neauesueneeneeeananeuneanueestenuasenonvnnncessnaganaeduusnasennasnauuenenssusansueauusenansuensunnenenestecvensuaassnesesoeensyqananusennsansuesnennacnnasUSneeqnenanesuresennanagueeeaeuhbenseeuannensenatuneensenneuvensensevnenenssenees
Operation No. of operation texts and work units or standard texts and flat rates:
Zero position of air flow sensor plate ……… determine by inspecting visually when engine not running. The inspection point is below the stop bar (arrow). The top edge of the air flow sensor plate must be flush with the top edge of the cylindrical part of the air funnel; set zero position according to condition.
tie = RA 07.3.1212-1612/1
Setting zero position of air flow sensor plate to do this: a) if position too high, carefully tap in guide pin (arrow) with a drift to an appropriately lower position (mixture control unit installed). b) if position too low, remove mixture control unit and carefully tap out guide pin slightly (arrow) from below.
Note Re-position guide pin very carefully so that it is not moved too far.
Avoid at all cause moving several times in both directions otherwise interference-fit seat of pin will be inadequate. Idling speed… ee ee ee ee set (see Diagnosis Manual Engine, Volume 1).
RA 07.3.1212-1612/2