Operation No. of operation texts and work units or standard texts
WIS 07.3-1652
Model 129
uth = RA 07.3.12114-1652/1 ignition switch off. Accessories compartment cover remove, install. CIS-E resistance trimming plug (R17) . unplug, plug in.
ZN
The CIS-E resistance trimming plug must be resealed after installing with the sealing pliers 124 589 01 37 00 and the stamping set 124 589 24 63 00. CIS-E control unit fault memory read out, erase if necessary (see Diagnosis Manual Engine, Volume 2, index 0).
Note Stored faults which may originate from test work resulting from cables being disconnected or from a simulation, must be erased in the fault memory after completing the work.
Special tools
apie = RA 07,.3.1211-1652/2
aqme = RA 07.3.1211-1652/3