Performing fuel quantity comparison measurement

WIS 07.3-1609

Performing fuel quantity comparison measurement – rysunek
Performing fuel quantity comparison measurement – rysunek

Operation No. of operation texts and work units or standard texts and flat rates:

Injection lines ….. scence eee eee eee unscrew at fuel distributor and at injection valves, screw on. Clean connection points beforehand. Fuel quantity comparison measuring instrument (064) 2… ee eee position horizontally next to vehicle and connect to fuel distributor (see notes at illustrations for sequence). Fuel return line of measuring instrument ……. insert into filler neck of fuel tank. Adjusting device for fixing air flow sensor plate ……….. eee eee ee eee eee clamp to stop bar of air flow sensor plate (see notes at illustrations). Engine systerns control unit (N16) 2. ……6.. disconnect, connect contacts terminal 30 and terminal 87 (see notes at illustrations, arrows). This causes fuel pump to run. Air flow sensor plate ……. ran deflect and press buttons 1 to 6 in turn to bleed instrurnent.

iin = RA 07.3.1211-1609/1 press and hold. Deflect air flow sensor plate Button Voce eeeeee wee with adjusting device far enough to achieve up to 4 cm*/min (idle speed quantity). Fix air flow sensor plate in place. Button: S2tOB ……… press in turn, measure flow quantities and enter on sheet B20 800.99.472.00. Maximum permissible variation of cylinders to each other 0.4 cm?/min (idling). Then, the same as described previously, test part and full load flow. Deflect air flow sensor plate for this purpose. a) Partload 30 cm*min b) Fullload 100 cm*/min Maximum perrnissible variation of cylinders to each other Part load = 4 cm/min Fullload = 10 em/min If variation out of tolerance, replace fuel distributor. Leak test of all fuel connections check with engine running. (set idle speed after performing comparison measurement of fuel quantities, see Diagnosis Manual Engine, Volume 1). CIS-E control unit fault mennory reac out, erase if necessary (see Diagnosis Manual Engine, Volume 2, Index 0).

Note Stored faults which may originate from test work as a result of disconnecting cables or from a simulation, must be erased in the fault memory after completing the work.

Performing fuel quantity comparison measurement – rysunek

Special tool

aptiiniye

RA 07.3.1211-1609/2

Performing fuel quantity comparison measurement – rysunek

Commercial tools and testers

be shop-made or obtained from a Bosch agency.

Note

Performing fuel quantity comparison measurement – rysunek

The measurement is perforrned with the engine not running. The operating condition (idle speed, part or full load) is simulated and set at the air flow sensor plate with an adjusting device.

Notes regarding illustrations

Performing fuel quantity comparison measurement – rysunek

Arrangement of fuel lines to fuel quantity comparison measuring instrument

Set air flow sensor plate with adjusting device

athe = RA 07.3.1211-1609/3

Performing fuel quantity comparison measurement – rysunek

Engine systems control unit connector

anihiye = RA 07.3.1211-1609/4