Engine cooling,  M110

Testing radiator or expansion tank closing cap

 

 

20—430 Testing radiator or expansion tank closing cap

 

Radiator or expansion tank closing cap

 

Pressure relief valve opens at
new cap
1.0 ^.q’]^ bar 9au9e pressure
used cap
1.0—0.2 bar gauge pressure
m110 - 0783-1.jpg
Vacuum valve opens starting at 0.1 bar vacuum

 

Special tools

 

Tester for cooling system and radiator cap
m110 - 0783-2.jpg
001 589 48 21 00

 

Double connection for radiator cap in combination with cooling system tester
m110 - 0783-3.jpg
000 589 73 63 00
11004-8326

 

Checking pressure relief valve
m110 - 0783-4.jpg
11004-8666
1    Attach double connection to leak tester by means of holding clips.
2   Place radiator cap on double connection.
3   Check opening pressure by pumping.

 

Checking vacuum valve

 

Vacuum valve (arrow) should rest against rubber seal, should lift off easily and snap back following release.
m110 - 0783-5.jpg

 

20.2-430/1 F3