Testing radiator or expansion tank closing cap
|
|||||||
20—430 Testing radiator or expansion tank closing cap
|
|||||||
|
|||||||
Radiator or expansion tank closing cap
|
|||||||
|
|||||||
Pressure relief valve opens at
|
new cap
1.0 ^.q’]^ bar 9au9e pressure
used cap
1.0—0.2 bar gauge pressure
|
||||||
Vacuum valve opens starting at 0.1 bar vacuum
|
|||||||
|
|||||||
Special tools
|
|||||||
|
|||||||
Tester for cooling system and radiator cap
|
001 589 48 21 00
|
||||||
|
|||||||
Double connection for radiator cap in combination with cooling system tester
|
000 589 73 63 00
|
||||||
11004-8326
|
|||||||
|
|||||||
Checking pressure relief valve
|
11004-8666
|
||||||
1 Attach double connection to leak tester by means of holding clips.
2 Place radiator cap on double connection.
3 Check opening pressure by pumping.
|
|||||||
|
|||||||
Checking vacuum valve
|
|||||||
|
|||||||
Vacuum valve (arrow) should rest against rubber seal, should lift off easily and snap back following release.
|
|||||||
|
|||||||
20.2-430/1 F3
|
|||||||
|
|||||||
Poprzedni