Testing pneumatic idle ‘speed increase (PLA)

WIS 07.1-2009

Testing pneumatic idle ‘speed increase (PLA) – rysunek

Preceding work: Operation no. of operation texts and work units or standard texts Testing, adjusting idle speed (07.1-2053). cs and flat rates:

10 In-line injection purnp 019 Vacuum tester 10/6 Governor housing 12/3 PLA vacuum unit a Air admission to interior

61 Restriction with fitter c Other consumers 61/1 Restriction with filter, white 61/3 Restriction, orange 64/1 Thermovalve, closes 30°C 104 Vacuum pump

Engine eee eee eee cee eee eee warm up to coolant temperature > 40°C. Vacuum tester (019) 22… ee eee eee eee connect and test supply vacuum. Specification: = 700 mbar. Thermovalve, closes 30°C (64/1) ………… test for leaks. PLA vacuum unit (12/3) …….0..0. see e eee test for feaks. Air admission line (SW)… ee eee test for clear passage.

«atin = RA 07.1.1621-2009/1

Testing pneumatic idle ‘speed increase (PLA) – rysunek
Testing pneumatic idle ‘speed increase (PLA) – rysunek
Testing pneumatic idle ‘speed increase (PLA) – rysunek

Note The PLA vacuum unit (12/3) at the injection pump can only be replaced at a Bosch dealership because the governor has to be disassembled and then set on a Bosch injection pump tester.

PO7-6474–15

eis = RA 07.1.1621-2009/2