Testing anti-jerk control (ARA)
WIS 07.1-1840
Operation no. of operation texts and work units or standard texts and flat rates:
Connection diagram of digital tester without adapter, location of cormponents
ote = RAQ7.1.1621-1840/1
Connection diagram of pulse counter, hand-held tester
013 Pulse counter X11/4 Test coupling for diagnosis (416-pin) 087 Hand-held tester Gi Battery
Pulse counter Black cable Terminal 31 (ground) or contact 1 Red cable Terminal 15 (ignition), terminal 30 (battery) or contact 16 Yellow cable Contact 4 (ARA, ELR/ARA control unit)
Hand-held tester Black cable Terminal 31 (ground) or contact 1 White cable Terminal 15 (ignition) or contact 16 Red cable Terminal 30 (battery), %4/10 (terrninal block) or contact 3 Yellow cable Contact 4 (ARA, ELR/ARA control unit)
agian = RAQ7.1.1621-1840/2
Digital tester (001) and pulse generator (021) see eee connect, disconnect. Accelerator control for ease of movement ….. . check.
check; the spring plate (29/7) must be resting Idle speed stop at Bowden cable (32) ……… free of tension against the cornpression spring (29/8). Overvoltage protection fuse 2… 0.0… eee test.
Battery voltage 2… 0. kee eee eee ee test, approx. 12 V. Measured at overvoltage protection between contacts 1 and 5.
Engine to coolant temperature of 60 – 80 °C warm Up.
Test with pulse counter Pulse counter (013) to battery (G1) and to test coupling (€11/4) 2. ee ee ee eee connect according to connection diagram, disconnect.
Note LED U-Batt in display panel must come on;
if not:
a) Test fuse of pulse counter. b) Test contact 1 of test coupling (X1 1/4) to battery positive (approx. 11 – 12 V). c) Test contact 4 of test coupling (11/4) to contact 1 (approx. 6 ~ 12 V). run at idle speed. ENQin® 2… ee ee eee ee et eee Start button of pulse counter (013) ………. . press for 2 ~ 4 saconds. Display ……. sete eee see eee ene read and note. Readout „1”: no fault Readout greater than „1”: fault in system press once again for 2 ~ 4 seconds. Start button of pulse counter (013) ……….. If there is no further fault in system, the previous readout reappears. If there is a further fault in the system, its fault code is displayed.
stim = RAQ7.1.1621-1840/3
Noted faults after test prograrn “testing individual components” ………. … rectify. Engine 605.911 see section ” Engine 606.910 see section ” Fault memory 2… 6… eee eee eee eee a erase by pressing start button of pulse counter and reading rectified fault. Then press start button for 6 – 8 seconds.
Note Each fault displayed must be erased individually. Once the fault has been rectified and erased, the fault code no longer appears during the fault output. Digit greater than 1 displayed, further faults in system.
Test with hand-held tester Hand-held tester (087) according to connection diagram …… stew shee e eee connect, disconnect. The test cycle is integrated in the HHT prograrn.
Note Reading, erasing fault memory, see operating instructions of hand-held tester.
Special tools
«gti RAQ7.1.1621-1840/4
Multimeter Sun, DMM-5 Fluke 23 DB, 83, 88 ITT Metrix MX 47, 50, 51, 52
Digital tester Sun, DIT 9100 AVL, Diesel-Tester 873 Bosch, ETD 019.02
Digital tester Bosch, MOT 103, 002.02, 150, 250 Engine diagnostic tester Hermann D960, D880 Bear, DEACE
Hand-held tester Mercedes-Benz AG 6511 0001 99 70322 Stuttgart 60 VP/SDI
Y distributor MB part no. 117 078 01 45
otiiige = RAQ7.1.1621-1840/5
ote = RAQ7.1.1621-184.0/6
b) Testing individual components, engine 606.910
eptiige RAO7.1.1621-184.0/7
emia = RAQ7.1.1621-1840/8