Testi vacuum cutoff for leaks

WIS 07.1-1842

Testi vacuum cutoff for leaks – rysunek

Operation no. of operation texts and work units or standard texts and flat rates:

10 In-line injection purnp c Other consumers 12/1 Stop vacuum unit e To brake booster

63 Brake check valve

66 Glow start switch valve 019 Vacuum tester 104 Vacuum pump

Glow start switch 2.2… eee eee move into position „0”. Suction lining (or) wwe eee Laces detach from connector of check valve (63). Vacuum tester (019) «2… eee teens connect to suction lining (br) (arrow) and pressurize with vacuum of 400 + 50 mbar. If a vacuum drop of more than 6 mbar/rnin occurs at vacuum tester (019), test the system for leaks.

cotige = RA O7.1.1621-1842/1

Testing Vacuum line (br/bl) to glow starter switch valve detach and seal. Pressurize with vacuum; if leak (66) exists, replace glow starter switch valve (66) (46-8010). connect to vacuum line (br/bl) to stop vacum Vacuum tester (019) ow… ee eee seen eee unit (12/1). Pressurize with vacuum; if leak exists, replace stop vacuum unit (12/1) (07.1-8618). connect. All detached vacuum lines

Testi vacuum cutoff for leaks – rysunek

Special tool

RA 07.1.1621-1842/2 seinen