Adjusting start of delivery with digital tester (RIV method)

WIS 07.1-8300

after testing

Adjusting start of delivery with digital tester (RIV method) – rysunek

Preceding work: Operation no. of operation texts and work units or standard texts Testing start of delivery (07.1-8244). and flat rates: 07.1-8300

Connection diagram of digital tester without adapter (with adapter, see 07.1-8244)

Securing bolts (arrows) on injection purnp flange and on supporting bracket ………… slacken. Engine ……….. see ee eee eee ee run at idle speed. Ril value (indirect start of delivery) ……….. adjust by turning the adjusting device (30/1). RI specification: 14° + 0.5° ATDC.

Direction of rotation of adjusting screw

(30/1) To right = start of delivery retarded To left = start of delivery advanced

ohn = RA 07.1.1621-8300/1

Note lf the adjustment facility is insufficient, the injection purnp must be turned over. See removing and installing injection pump (07.1-8410).

switch off. Securing bolts (arrows) at injection pump flange and at supporting bracket ………….00.. tighten. Tightening torque 20–25 Nm. disconnect. Screw plug (arrow) at governor (10/6) ……… screw in. Tightening torque 30–35 Nm. Leak test with engine running perform. Engine oil level check, adjust to correct level if necessary.

Adjusting start of delivery with digital tester (RIV method) – rysunek
Adjusting start of delivery with digital tester (RIV method) – rysunek
Adjusting start of delivery with digital tester (RIV method) – rysunek

Special tools

RA 07.1.1621-8300/2