Adjusting microswitch at injection pump

WIS 07.1-8317

Adjusting microswitch at injection pump – rysunek
Adjusting microswitch at injection pump – rysunek

Operation no. of operation texts and work units or standard texts and flat rates:

PO7-6212–13

Engine 605.911 Intake manifold remove, install (14-1310). Bracket at rear of injection pump remove, install.

Engine 606.910 Resonance intake manifold 0.0.0… e ae remove, install (14-1961).

All models

Vacuum control valve oo… ee ee remove, install. Locking bolt (8d) of adjusting cam slacken. Gauge (8c) fit on to full load stop. Adjusting lever (16) of injection purnp tum until it is resting against the gauge (8c).

Adjusting without multimeter Adjusting cam (8e) turn counter-clockwise until both microswitches are heard to operate (clicking noise).

coi RA 07.1.1621-8317/1

Adjusting with multimeter Adjusting cam (8¢e) turn counter-clockwise until the readout in multimeter is © 2 (see connection illustration).

Note

Adjusting microswitch at injection pump – rysunek

Microswitch ($27/6) operates at 15° and 10° before full load. Locking bolt (8d) of adjusting cam ……… tighten and remove gauge.

Adjusting microswitch at injection pump – rysunek

Shop-made tool Gauge 250 mm long, 3 mm dia. wire. Washer outer dia. 30 mm, inner dia. 10 mrn. The wire must be welded to the washer:

Connection diagram of microswitch Unplug coupling at microswitch (S27/6) and connect multimeter to connector 1 and 3.

site = RA 07,1.1621-831 7/2