WIS 15-505
WIS 15-505
Ontact breaker points
Dwell angle (normal coil ignition)
| Test and adjusting value at idle’) | Change between idle and 3000/min |
| 47–53° | max. + 3° |
| 1) Do not change dwell angle with used contacts, renew contacts when attaining lower test value. When installing new contacts, set dwell angle to 53 + 1°. Dwell angle (transistorized ignition system) Identification: Blue ignition coil, two pre-resistors and transistorized ignition switching unit. | |
| and adjusting Testing value with used contacts at idle*) | Change between idle and 3000/min |
| 47–53° | max. + 3° |
| 2) When installing new and when adjusting used contact breaker points, set dwell angle to 47 + 1°. Conventional tools | |
| Dwell angle meter, revolution counter | |
| Digital tester | e.g. made by Bosch, MOT 001.03 |
Conversion of dwell angle values from % into 4°
>» . x cylinders x 100 % = 360
oL- % x 360 100 x cylinders
Installation
When renewing contact breaker points, proceed as follows:
1 Rub contacts prior to installation with a lintfree cloth to remove moisture or grease.
2 Coat slide piece of contact breaker, its bearing point and the cams of the distributor shaft with some Bosch special grease Ft 1 v 4.
3 Inclosed condition, the contacts should be in parallel and at uniform height in relation to each other.
Arrow: Spot to be greased
4 Check dwell angle and firing point and adjust, if required (15—500).