WIS 15-505

WIS 15-505

Ontact breaker points

Dwell angle (normal coil ignition)

Test and adjusting value at idle’)Change between idle and 3000/min
47–53°max. + 3°
1) Do not change dwell angle with used contacts, renew contacts when attaining lower test value. When installing new contacts, set dwell angle to 53 + 1°. Dwell angle (transistorized ignition system) Identification: Blue ignition coil, two pre-resistors and transistorized ignition switching unit.
and adjusting Testing value with used contacts at idle*)Change between idle and 3000/min
47–53°max. + 3°
2) When installing new and when adjusting used contact breaker points, set dwell angle to 47 + 1°. Conventional tools
Dwell angle meter, revolution counter
Digital testere.g. made by Bosch, MOT 001.03
WIS 15-505 – rysunek

Conversion of dwell angle values from % into 4°

>» . x cylinders x 100 % = 360

oL- % x 360 100 x cylinders

WIS 15-505 – rysunek

Installation

When renewing contact breaker points, proceed as follows:

1 Rub contacts prior to installation with a lintfree cloth to remove moisture or grease.

2 Coat slide piece of contact breaker, its bearing point and the cams of the distributor shaft with some Bosch special grease Ft 1 v 4.

WIS 15-505 – rysunek

3 Inclosed condition, the contacts should be in parallel and at uniform height in relation to each other.

Arrow: Spot to be greased

4 Check dwell angle and firing point and adjust, if required (15—500).