Checking idle speed stabilization on engines with refrigerant compressor

WIS 07.3-145

Conventional tool

Voltmeter, revolution counter

e.g. made by Bosch, MOT 001.03 Digital tester

Testing

Checking idle speed stabilization on engines with refrigerant compressor – rysunek

1 Run engine at idle. When adding refrigerant compressor, the idle engine speed should increase by approx. 80/min.

If the idle speed is not increasing, pull upper and lower vacuum line from switchover valve (43).

Vacuum should be available at upper line.

Checking idle speed stabilization on engines with refrigerant compressor – rysunek

Model 107 43 Switchover valve (mounted on mounting bracket for coolant expansion tank).

Layout switchover valves (43).

Checking idle speed stabilization on engines with refrigerant compressor – rysunek

Model 123

Model 126 43 Switchover valve air conditioning (identification: green cap) 43a Switchover valve decel shutoff (identification: gray cap)

Checking idle speed stabilization on engines with refrigerant compressor – rysunek

1 Mixture controller 43 Switchover valve rpm increase Color code

10 Idle speed air screw air conditioning gn =green

11 Decel circulating air valve 96 Supplementary air valve vi = purple

14 Bypass valve air conditioning a Connection switchover valve ws = white

39 Relay air conditioning decel shutoff c To idle speed air duct in intake manifold

Checking idle speed stabilization on engines with refrigerant compressor – rysunek

Note: For operation decel shutoff and idle speed stabilization refer to 07.3–500.

2 Connect both vacuum lines with each other, idle speed should then increase by approx. 80/min. If not, renew bypass valve (14).

Checking idle speed stabilization on engines with refrigerant compressor – rysunek

3 If the engine speed increases, check electric activation of switchover valve (43). For this purpose, pull off coupler: with refrigerant compressor switched 1

on, battery voltage should be available. If voltage is available, replace switchover valve. If no voltage is available, test voltage supply according to wiring diagram (refer to wiring diagram group 83 Air conditioning system).

1 Euel pump relay e Refrigerant compressor 1073-10361