Checking choke cover-stepped heater

WIS 07.2-145

A. @ 1976

Test conditions: All fuses in order, engine at operating temperature, run engine at idle.

Wiring diagram (drawn with ignition switched off below 17 °C engine oil temperature)

Checking choke cover-stepped heater – rysunek

Choke cover-stepped heater, automatic choke, positive and negative venting of float chamber

5 Relay box 33 Switchover valve air injection (blue) 48 Choke cover

7 Temperature switch 17 °C 37 Switchover valve float chamber 59 Starter lockout and back-up lamp switch

12 Switchover vaive EGR (brown) Positive ventilation (green) 241 Switchover valve automatic choke

32 Temperature switch 65 °C 46 Resistor 8 ohms (white)

Color code

bl = blue rs = pink vi = purple a Fuse no. 4 br = brown rt = red ws = white b Coupler to main conductor ge = yellow sw= black Cable color purple — starter terminal 50 Cable color purple/white — starter switch terminal 50 c Warning switch catalyst temperature

Checking choke cover-stepped heater – rysunek

Connect voltmeter at output of resistor (46) and connect to ground. Disconnect plug connection of electric line to temperature switch 17 °C (7) and connect to ground.

Checking choke cover-stepped heater – rysunek
Checking choke cover-stepped heater – rysunek

Voltmeter indicating Voltmeter not 7–8 volts. indicating 7–8 volts.

Test relay box (5)

Connect voltmeter at input of resistor (46) and to ground.

Connect plug connection of temperature switch (7) to ground. Voltmeter should indicate 7–8 volts.

Checking choke cover-stepped heater – rysunek

If no voltage is measured, renew relay box (5).

voltmeter at output of resistor (46) ground.

from temperature switch 65 °C.

indicating Voltmeter not indicat12 volts. ing approx. 12 volts.

al

Checking choke cover-stepped heater – rysunek

Renew relay box (5).

End of test

B. 1976

Test conditions: All fuses in order, engine at operating temperature, run engine at idle.

Wiring diagram (drawn with ignition switched off, below 17 °C engine oil temperature)

Choke cover-stepped heater, EGR

Checking choke cover-stepped heater – rysunek

Color code

bl = blue rs = pink vi = purple br = brown rt = red ws = white ge = yellow sw = black

a Fuse no. 3 (15/54) b Relay starter terminal 85 c Relay starter terminal 86

7 Temperature switch 17 °C 12 Switchover valve EGR (brown) 46 Pre-resistor 8 ohms 47 Relay pre-resistor choke cover 48 Choke cover 49 Starter lockout and back-up light switch

Connect voltmeter to output of resistor (46) and to ground. Disconnect plug connection of electric line to temperature switch 17 °C (7) and connect to ground.

Checking choke cover-stepped heater – rysunek

Voltmeter indicating Voltmeter not 7–8 volts. indicating 7–8 volts.

Test relay pre-resistor choke cover (47)

Connect voltmeter one after the other to both connections of pre-resistor choke cover (46) and to ground.

Checking choke cover-stepped heater – rysunek

Connect plug connection of temperature switch 17 °C (7) to ground. Voltmeter should indicate approx. 7–8 volts once.

If no voltage of 12 volts is measured, test choke cover.

\f less than 7–8 volts are measured, test pre-resistor or renew relay.

all er

Connect voltmeter to output of resistor (46) and to ground.

Pull plug from temperature switch 65 °C.

Voltmeter indicating Voltmeter not indicatapprox. 12 volts. ing approx. 12 volts.

If less than 7–8 volts are measured, test pre-resistor or replace relay.

End of test

C. 1973/74

Test conditions: All fuses in order, engine at operating temperature, run engine at idle.

Wiring diagram (drawn with ignition switched off, below 17 °C engine oil temperature)

Choke cover-stepped heater, throttle valve lift

Checking choke cover-stepped heater – rysunek
Checking choke cover-stepped heater – rysunek

4 Rpm relay with 2 speeds 9 Switchover valve ignition 46 Resistor choke cover 1800/2000/min and 3000/3400/min 10 Switchover valve throttle valve lift 47 Relay resistor choke cover

5 Relay box (8-pole) 12 Switchover valve EGR 48 Choke cover 5a Relay box (12-pole) 13. Vacuum switch 0.2 bar 52 Relay temperature switch 17 OC

7 Temperature switch 17 °C 16 Oil pressure switch 1.2 bar

8 Temperature switch 100 °C 32 Temperature switch 65 °C

Color code

bl = blue gn = green sw = black a Fuse no. 3 br = brown rs = pink vi = purple b Double cable connector terminal 1 ZV ge = yellow rt = red ws = white c Relay air conditioner terminal 87a

Checking choke cover-stepped heater – rysunek

Disconnect plug connection of electric line to temperature switch 17 °C (7) in oil filter housing and connect to ground.

Checking choke cover-stepped heater – rysunek

Relay (47 and 52) audibly switching. not switching.

Test relay for resistor of choke cover (47) (front relay, short cable)

Connect voltmeter to output of resistor (46) and to ground. With the ignition switched on, the voltmeter should indicate approx. 13 volts. If there is no voltage, renew relay (47).

Loosen plug connection of electric line to temperature switch 17 °C and connect to ground. Voltmeter should indicate approx. 5 volts. If there is no voltage, renew resistor.

If approx. 13 volts are measured, exchange choke cover on carburetor and repeat test.

End of test

D. @s9 1974 California

Test conditions: All fuses in order, engine at operating temperature, run engine at idle.

Wiring diagram (drawn with ignition switched off, below 17 °C engine oil temperature)

Choke cover-stepped heater, fuel evaporation control system

Checking choke cover-stepped heater – rysunek

3 Temperature switch 62 °C 21° Switchbox 33 Switchover valve air injection

7 Temperature switch 17 OC 25 Relay disconnection temperature 37 Switchover valve fue! evaporation

8 Temperature switch 100 °C switch 62 °C/100 °C control system

9 Switchover valve ignition 26 Relay auxiliary fan 46 Resistor choke cover

12 Switchover valve EGR 27 Auxiliary fan 47 Relay resistor choke cover 13. Vacuum switch 32 Temperature switch 65 °C 48 Choke cover

Color code

bl = blue gn = green sw = black To two-point cable connector terminal 7 (TD) aroaang»gn br = brown rs = pink vi = purple Switch air conditioning system ge = yellow tt = red ws = white Fuse no. 3 (15/54) Fuse no. 4 (15/54) Auxiliary fuse box for auxiliary fan 4-point plug on relay holder 2-point coupler, tied-up

Checking choke cover-stepped heater – rysunek

Disconnect plug connection of electric line to temperature switch 17 °C (7) in oil filter housing and connect to ground.

Relay (47) audibly Relay (47) not switching. switching.

Checking choke cover-stepped heater – rysunek

Pr

Test relay in switchbox (21)

Pull coupler from relay for resistor of automatic choke and connect voltmeter to terminal 1 and 3. Loosen plug connection of electric line to temperature switch (7) and connect to ground.

With the ignition switched on, the voltmeter should indicate approx. 13 volts. If no voltage is measured, renew switchbox (21).

Test relay for resistor of choke cover (47)

Connect voltmeter to output of resistor (46, upper connection) and to ground. With the ignition switched on, the voltmeter should indicate approx. 13 volts. \f no voltage is measured, renew relay (47).

Loosen plug connection of electric line to temperature switch (7) and connect to ground. Voltmeter should indicate approx. 5 volts. If no voltage is measured, renew resistor.

If approx. 13 volts are measured, exchange choke cover on carburetor.

End of test

E. @ 1975/76

Test conditions: All fuses in order, engine at operating temperature, run engine at idle.

Wiring diagram (drawn with ignition switched off, below 17 °C engine oil temperature)

Checking choke cover-stepped heater – rysunek
Checking choke cover-stepped heater – rysunek

Choke cover-stepped heater, automatic choke, tank breather

5 Relay box 33 Switchover valve air injection (blue) 48 Choke cover

7 Temperature switch 17 °C 37 Switchover valve float chamber 49 Starter lockout and back-up light switch

12 Switchover valve EGR (brown) positive vent (green) 241 Switchover valve automatic choke

32 Temperature switch 65 °C 46 Resistor 8 ohms (white)

Color code

bl = blue rs = pink vi = purple a Terminal 50 starter br = brown rt = red ws = white b Fuse no. 3 ge = yellow sw = black c Terminal 30 emergency starter switch

07.2.2 1la~145/9

Testing choke cover-stepped heater Connect voltmeter to output of resistor (46) and to ground. Disconnect plug connection of electric line to temperature switch 17 °C (7) and connect to ground.
Voltmeter indicating 7–8 volts.Voltmeter not indicating 7–8 volts.
Test relay box (5) Connect voltmeter to input of resistor (46)
and to ground. Connect plug connection of temperature switch to ground. Voltmeter should indi- cate 7–8 volts. If no voltage is measured, renew relay box (5).
dl
_ Testing choke cover-stepped heater Connect voltmeter to output of resistor (46) and to ground. Pull plug from temperature switch 65 °C.
Voltmeter indicating approx. 12 volts.Voltmeter not indi- cating approx. 12 volts.
Renew relay box (5).
Checking choke cover-stepped heater – rysunek
Checking choke cover-stepped heater – rysunek
Checking choke cover-stepped heater – rysunek
Checking choke cover-stepped heater – rysunek

End of test