Checking and correcting choke housing mark

WIS 07.2-142

Testing and adjusting values

Distance ‘’a’’ between choke housing and driver (197)approx. 1.0 mm
Choke cover preload Checking, correctingto mark
Checking and correcting choke housing mark – rysunek

1 Check whether driver (196 and 197) is at right angle in relation to choke housing and bend lever accordingly, if required.

2 Operate throttle valve lever by half, push driver (196 or 197) to the left up to stop.

3 Check whether choke valve is closed free of play and distance ‘’a’’ between driver (197) and choke housing amounts to approx. 1.0 mm.

Checking and correcting choke housing mark – rysunek

4 Disconnect choke rod, if required, and bend as needed.

Attention! To avoid distortion of driver (196), support choke rod.

Checking and correcting choke housing mark – rysunek

5 Actuate throttle valve lever by half. Push driver (194 or 196) to the left up to stop.

Rebending choke rod

Checking and correcting choke housing mark – rysunek

6 Check marking notch (arrow) in extension of driver (194 or 196) and punch in new notch, if required.