Testing restrictor in fuel distributor for clear passage

WIS 07.3-1604

Testing restrictor in fuel distributor for clear passage – rysunek

Preceding work: Operation no. of operation texts and work units or standard texts Testing fuel pressures and internal leaktightness (07.3-1603). —_ and flat rates: 07-1604.

Coupling at actuator ………….-…045. unplug. If lambda control fitted, switch on ignition. Separate coupling of oxygen sensor in interior of vehicle. Fuellinge 0… cee eee ee eee unscrew at fuel distributor and seal with M10 1 screw plug. Pressure hose… 6. ee ee eee ee eee connect at fuel distributor and hold in measuring glass or beaker (057). Special! tool 102 589 00 21 05.

wii = =RA 07.3.1112-1604/1

Fuel pump relay Se eee eee eee remove and bridge contacts 7 and 8, on model 129 engine systems control unit MAS between contacts 1 and 2 for @s® CG) as of model year 1990 on KE control unit (N3) between contacts 11 and 20 (fuel pump runs). Special tool 201 589 00 99 00. Contact bridge wee eee eee remove after 1 minute. Special tool 201 589 00 99 00. Restrictor …… See eee eee eee eee eee check for clear passage. Specification: 130-150 cm3/min at minimum voltage of 11.5 V at fuel pump. If specification is not achieved, replace fuel distributor.

Special tools

Testing restrictor in fuel distributor for clear passage – rysunek
Testing restrictor in fuel distributor for clear passage – rysunek

Commercially available tools and testers (see Workshop Equipment Manual) Designation e.g. Make, order no.

Multimeter Sun, DMM-5

Measuring glass or beaker

Stop watch

Testing

1 Unplug coupling at actuator. If lambda control fitted, switch on ignition. Separate coupling of oxygen sensor in interior of vehicle.

wie = RA 07.3.1112-1604/2

Testing restrictor in fuel distributor for clear passage – rysunek

2 Screw fuel connection line (arrow) between fuel distributor and diaphragm pressure regulator onto fuel distributor. Seal unscrewed connection line with M10 X 1 screw plug so that no fuel flows out.

Testing restrictor in fuel distributor for clear passage – rysunek

3 Connect fuel pressure hose to fuel distributor and hold in measuring glass or beaker.

Testing restrictor in fuel distributor for clear passage – rysunek

4 Remove fuel pump relays (N16/1 to N16/4).

Shown on models 124, 201

tie =—-RA 07.3.1112-1604/3

Testing restrictor in fuel distributor for clear passage – rysunek

§ Bridge contacts 7 and 8, on model 129 engine systems control unit MAS between contacts 1 and 2, for ©) as of model year 1990 on KE control unit (N3) between contacts 11 and 20. This energizes the fuel pump.

Remove contact bridge after 1 minute.

If the specification of 130-150 cm3/minute at a minimum voltage of 11.5 volts at the fuel pump is not achieved, replace fuel distributor.

ime =RA 07.3.1112-1604/4