Testing kickdown switch

WIS 07.3-1122

Testing kickdown switch – rysunek
Testing kickdown switch – rysunek
Testing kickdown switch – rysunek

Operation no. of operation texts and work units or standard texts and flat rates: 07-1122.

P07-5379–57
$16/7_ Y3 Commercially available tools and testers (see Workshop Equipment Manual)Kickdown switch 003 Solenoid valve (kickdown valve, automatic transmission)Multimeter
Designatione.g. Make, order no.
MultimeterSun, DMM-5

wie RA 07.3.1112–1122/1

Testing kickdown switch – rysunek

Special tool

Test

Symbols for testers Symbols for test mode with multimeter

Multimeter =@* = Multimeter —t Socket DC voltage mode _ Connector = Multimeter a Ground Resistance mode

Note See appropriate wiring diagrams volume for wiring diagrams.

iim = RA 07.3.1112-1122/2

Testing kickdown switch – rysunek

wii §=RA 07.3.1112-1122/3

Test stepRequirementSpecifi- cation/ FunctionPossible cause/Remedy
2.1position „E” position „S”OFF mode<1QSelector mode switch (S16/5)
3.0switch hand.from valve kick-11-14VOpen circuit in wiring
Testing kickdown switch – rysunek

4.0 dis11-14V Open circuit in wiring S16/7, switch- Fuel pump relay (up to valve 09/85)

kickswitch hand. mode (S16/5) position ”E”

Location of kickdown valve (Y3)

Testing kickdown switch – rysunek

Y3 Kickdown valve, automatic transmission

whe §=RA 07.3.1112-1122/4