Replacing air flow sensor
WIS 07.3-1686
Preceding work: Operation no. of operation texts and work units or standard texts Removing and installing mixture controt unit with air guide and flat rates: housing (07.3-1668). 07-1686.
Air guide housing (27) ……..-.-..–.206unscrew from mixture contro! unit (1). Replace any damaged parts. When installing, do not use any sealing compound. Component is sealed by sealing lip (arrow).
Note The air guide housing is made of rubber. It is fitted into the light alloy frame for securing. Fuel distributor (3) …………—22–05remove, install (07.3-1674).
wie §=RA 07.3.1132-1686/1
Note
Bolts of different lengths are used for attaching the air guide housing to the air flow sensor. For this reason, it is essential when installing to ensure that the bolt removed below the air flow sensor position indicator (arrow) is also reinserted at that point. Ifa longer bolt is used, the air flow sensor position indicator will be damaged.
Note
Models 107, 124, 126
Installation security is improved by means of an M 6 X22 bolt + washer (arrow). Previous version: M 6 X 20 bolt + washer.
Production breakpoint: July 1986
Model Engine Engine end no. Engine end no. manual transmission automatic transmission
107.041 103.982 000665 003298
124.026 103.940 009175 006177
006856 037949 124.030/090 103.983
126.020 103.941 001130 004695
126.024/025 103.981 002496 019170
When detaching the fuel line (50) from fuel distributor to diaphragm pressure regulator, ensure that the open-end wrench does not press on the air flow sensor position indicator and damage it.