Replacing vent connection at radiator
WIS 20-4270
Preceding work: Warning instructions when hood open (01-0085).
P20 – 5135 – 57
Coolant at radiator ……………202–0– drain, pour in (20-0100). Coolant hoses (17) and (18) at radiator …….. disconnect, fit on. Connection fitting (19) illuminate from inside with rod lamp. Straight ring wrench (9mm) ………..—- fit onto connection fitting (19). Screwdriver (arrow) ……..-…2–2——- fit in place and push out connection fitting. New connection fitting ……………..0.0. insert.