M110,  Mechanical gazoline injection system CIS

Replacement, centering and zero position of air flow sensor plate

 

 

07.3—245 Replacement, centering and zero position of air flow sensor plate

 

Tightening torque
Nm

 

Hex. screw
5.0-5.5

 

Special tool

 

Torque wrench 1/4″ square, 4—16 Nm
m110 - 0506-1.jpg
000 589 67 21 00

 

Conventional equipment and tools

 

Hot air blower, tap M 6

 

Removal
m110 - 0506-2.jpg
1 Remove air cleaner.
2 Unscrew stop bracket.

 

3   Heat fastening screw with a hot air blower and screw out with care (risk of tearing threads).
Attention!
The fastening screw is micro-encapsulated.
4   Clean bore for fastening air flow sensor plate with M 6 tap.

 

07.3.2 Ma—245/1 F2

 

 

 

Installation

 

5 Install parts contained in repair kit. Make sure that the letters “TOP” are on top and insert air flow sensor plate. Lightly screw-in micro-encapsulated fastening screw (self-locking).

 

6 Center air flow sensor plate. For this purpose, pull off fuel pump relay (arrow) and bridge the two jacks short, or pull off plug on safety switch. Switch-on ignition for a short moment to establish control pressure.
Prior to September 1981: Jacks 1 and 2 Starting September 1981: Jacks 7 and 8
m110 - 0507-1.jpg

 

Use slip gauge 0.10—0.20 mm and make sure that the air flow sensor plate is accurately centered. Plate should not bind even under light lateral pressure (bearing play cancelled).
m110 - 0507-2.jpg

 

7 Tighten fastening screw to 5.0—5.5 Nm.

 

07.3.2 lla-245/2 F2

 

 

 

8 Check air flow sensor plate for easy operation. For this purpose, push plate down manually. Plate should not bind. Release plate, which should also not bind when moving back and should audibly abut against resilient contact. Center air flow sensor plate again, if required.

 

9 Check zero position (rest position) of air flow sensor plate. Upper edge of plate should close accura-rately flush with cylindrical part of of air funnel (arrow) along entire circumference. A higher location up to max. 0.5 mm is permitted.
Note: To check zero position, bridge electric safety circuit (refer to item 6). This will provide control piston with control pressure.
m110 - 0508-1.jpg

 

10 Adjust zero position of air flow sensor plate:
a)   If too high, lock guide pin (arrow) by means of a mandrel to required depth.
b)   If too low, remove mixture controller and knock-in guide pin from below (07.3—200).
Attention!
Do not knock-in guide pin too low.
Avoid repeated adjustments in both directions, since the press fit of the pin will become too loose.
m110 - 0508-2.jpg

 

11    Mount stop bracket and fuel pump relay or attach plug to safety switch.
12    Adjust idle speed (07.3-100).

 

07.3.2 lla-245/3
F 2