Checking sensor

WIS 54-520

Checking sensor – rysunek

1 Remove cover under instrument panel or instrument cluster.

2 Pull 2-pole coupling from sensor (3).

3 Connect Ohmmeter to sensor (3). On 1st version resistance should amount to 50—106 Ohms and on 2nd version to 650—1370 Ohms.

4 \f this value is exceeded or not attained, replace sensor (3).

Checking sensor – rysunek

1st version

2nd version