Checking cable control
WIS 54-525
1 Remove air cleaner.
2 Advance regulating linkage (13) to full throttle, the wire strand should move for approx. 20 mm without any resistance within cable control envelope (14).
3 Check adjustment, while strand should rest against regulation free of tension and with minimum play.