Operation of preglow system

WIS 15-705

A. General information

On a diese! engine, combustion is effected by selfignition of the fuel sprayed into the highiy compressed and thereby highly heated combustion air.

In the cold engine, the self-ignition temperature is not attained by compression alone. A preglow system is therefore required, which serves the purpose of increasing the temperature of the compressed air to facilitate the firing of the cold engine by the ignition of fuel particles on filament of glow plug.

Operation of preglow system – rysunek

The duration of preglowing depends on temperature of engine and on ambient temperature.

Design of pencil element glow plugs

Pencil element glow plugs consist essentially of a housing with M 12 x 1.25 screw-in threads and a pencil element pressed into housing.

The single-pole connecting pin is glued to housing by means of a non-releasable round aluminum nut.

The pencil element glow plugs are designed for a current of 11 volts and are operated in parallel.

The pencil element is heated indirectly by means of a heater element. This heater element, a coil made of a resistance wire, is embedded and insulated in a ceramic compound.

Operation of preglow system – rysunek

When the glow system is switched on, each glow plug is subject to a current of approx. 20 amps (peak impulse of approx. 40 amps).

Under the influence of increasing heat, the inherent resistance of the glow plug increases and will limit the current to approx. 8 amps.

a Current curve of pencil element glow plug

Operation of preglow system – rysunek

After a glow period of approx. 20 seconds a heater pencil element temperature of 900 °C/1652 °F will be attained, after approx. 50 seconds the max. temperature will be 1080 °C/1976 °F.

a Temperature curve of pencil element glow plug t {s]

Design of quick-start pencil element glow plugs

Except for heater element, the design of a quick-start pencil element glow plug is the same as that of a pencil element glow plug.

As an external identification, the connecting pin is screwed to the housing by means of a non-releasable round brass nut.

The heater element consists of a heater and control coil connected in series.

Operation of preglow system – rysunek

Ai When the glow system is switched on, each glow plug will be subject to a current of approx. 30 amps.

The glow plug is heated very quickly by heater coil. With increasing temperature, the control coil increases its resistance and limits the current to approx. 8–15 amps. This will protect the glow plug against overloads.

Operation of preglow system – rysunek

10 20 30 40 tgs b Current curve of quick-start pencil element glow plug

After a glow period of 9 seconds a pencil element temperature of approx. 900 °C/1652 °F is attained, after 30 seconds the max. temperature amounts to 1180 °C/1976 °F.

b Temperature curve of quick-start pencil element glow pluq

B. Preglow system engine 617.950 @s)1978–1980

General information

Operation of preglow system – rysunek

The essential components of the preglow system are the pencil element glow plugs, model year 1980 quickstart pencil element glow plugs, preglow time relay, temperature sensor and preglow indicator lamp.

Wiring diagram

1 Preglow time relay G1—G5 Pencil element glow plugs

2 Temperature sensor preglow system a Cable connector engine harness terminal 30

3 Temperature sensor coolant b_ Relay air conditioning/starter terminal 50

4 Preglow indicator lamp c Plug instrument cluster jack 3

Operation of preglow system – rysunek

The pencil element glow plugs are designed for a current of 11 volts and connected in parallel. For this reason, preglowing will proceed even if one pencil element glow plug fails.

Preglow time relay

The preglow time relay is located in engine compartment at left of wheel house.

Operation of preglow system – rysunek

Upon removal of clipped-on cap on preglow time relay the 80-amps fuse and the electric connections will be accessible.

Functions of preglow time relay

The preglow time relay has the following functions:

– Switching of glow current ~ Ready-to-start indicator — Safety shutoff — Fault indicator

When the preglow system is switched on in key position ‘’2” (preglowing, driving) the preglow time relay is activated by terminal 15 of starter switch.

The power relay in preglow time relay closes the circuit of terminal 30 (battery +) via 80-amps fuse to pencil element glow plugs.

When the key is turned into position ‘’3” (start) the power relay — activated by terminal 50 — remains in energized condition. The glow process continues until the key is turned to position “2”.

Operation of preglow system – rysunek

Ready-to-start indicator

A temperature sensor installed in coolant circuit determines the glow period in preglow time relay.

When the glow system is switched on, the preglow indicator lamp in instrument cluster lights up.

Operation of preglow system – rysunek

As soon as the required glow period, depending on coolant temperature, is attained, the preglow indicator lamp goes out and thereby indicates ready-tostart condition.

If there is no start following indication of ready-tostart condition, the glow current is interrupted by the safety shutoff, after 90 + 20 seconds for model year 1978/1979, after 50 + 10 seconds for model year 1980.

For subsequent starting, the glow system is again switched on via terminal 50 for the duration of the starting procedure.

Fault indicator

A functional fault of the preglow system is indicated by the preglow indicator lamp during or after the preglowing has been completed.

The preglow indicator lamp is controlled by the electronic system in preglow time relay.

Operation of preglow system – rysunek

flash for approx. 30 seconds after the preglow system has been switched on.

If one or several pencil element glow plugs or lines are interrupted, the preglow indicator lamp will flash for approx. 30 seconds after starting.

For preglowing, the current flows through the Reed contact coils located in respective glow current circuits.

The resulting magnetic field will close the Reed contacts and a voltage from terminal 15 will be applied to electronic system.

If this voltage is interrupted, for example by a failing pencil element glow plug (the respective Reed contact remains open) the preglow indicator lamp will flash for approx. 30 seconds after starting.

C. Preglow system engine 617.95 standard version and Gs® starting 1981

General information

The preglow system corresponds in principle to system of model year 1980.

Operation of preglow system – rysunek

The preglow time relay has been modified. In addition, the temperature sensor in coolant circuit is no longer installed.

Wiring diagram Pregiow time relay ft To fuse box terminal 15 = epAXTH Power relay 9 To plug connection starter lockout and backup lamp Electronics switch terminal 50 Temperature sensor (NTC resistor) G1—G5 Pencil element glow plugs Reed relay Preglow time relay To cable connector engine harness Terminal 30 in model 123 To point of support in fuse box Terminal 30 in model 126

Operation of preglow system – rysunek

Preglow time relay

The preglow time relay is located in engine compartment at left on wheel house.

After removing plugged-on protective cap, the electrical connections as well as the fuse strip are accessible.

Operation of preglow system – rysunek

Relay layout on engine 617.951

Relay layout on engine 617.952

The temperature sensor installed up to now in coolant circuit is no longer installed. Instead, the relay or relay ambient temperature is obtained by means of an NTC resistor in preglow time relay.

The preglow time relay has the following functions:

— Switching of glow current — Ready-to-start indicator — Safety shutoff — Fault indicator

Operation of preglow system – rysunek

Switching 0 of f glow current

When turning key into position ‘2’ (preglowing, driving) the preglow time relay (current on terminal 15) is switched on. The power relay (a) closes the circuit of terminal 30 (plus) via fuse for pencil element glow plugsG1—G5.

Power relay oo Electronic unit c Temperature sensor (NTC resistor) d Reed relay

When the key is moved into position ‘’3”’ (start) the power relay (a) remains in energized condition under influence of terminal 50, Glowing continues until key is again turned into position “2”.

Ready-to-start indicator

A temperature sensor installed in preglow time relay determines the duration of the glow period.

Operation of preglow system – rysunek

When the glow system is switched on, the preglow indicator lamp in instrument cluster lights up.

As soon as the required glow period, depending on ambient temperature of preglow time relay, has been attained, the preglow indicator lamp will go out and thereby indicate ready-to-start condition.

— Ticj a Pregiow period

Safety shutoff

Operation of preglow system – rysunek

If, upon indication of ready-to-start condition, there is no start within 20–35 seconds, the glow current is interrupted by the safety shutoff. For a subsequent start, the glow system is again switched on for the duration of the starting procedure.

The safety shutoff is no longer fixed, but is the result of the time up to ready-to-start condition (preglow indicator lamp goes out) plus 20 to 35 seconds.

a_ Preglow period b Safety shutoff Te}

Fault indicator

A fault in preglow system is indicated by the preglow indicator lamp not lighting up when key is actuated in position 2’.

The following faults are recognized:

— Interruption of line to connection terminal 30. ~ Fuse 80 Amps. defective. -— Power relay in preglow time relay defective.

— Interruption of one or several lines to pencil element glow plugs. — Interruption of one or several pencil element glow plugs.

Operation of preglow system – rysunek

Note: In the event of unfavorable tolerances of pencil element glow plugs or of Reed relay (d), response of fault indicator only after two pencil element glow plugs are defective is allowed.

Faults (monitoring of pencil element glow plugs) are indicated by comparing the current of the pencil element glow plug G 1 with current of remaining pencil element glow plugs G 2 to G 5 connected in Parallel.

Power relay ooo Electronic unit Temperature sensor (NTC resistor) d Reed relay

The currents of the two lines to pencil element glow plugs G 1 and G 2 to G 5 are flowing through two oppositely oriented Reed relay windings having a different number of turns in windings.

If the current flow in both windings is the same, the magnetic fields will cancel each other and the Reed contact will not respond.

Operation of preglow system – rysunek

If the balance of the magnetic fields is interrupted by the failure of one or several pencil element glow plugs, the Reed contact will close and the electronic unit (b) will be activated.

The preglow indicator lamp will switch off immediately and will therefore not light up when preglowing starts.

Power relay oo Electronic unit c Temperature sensor (NTC resistor) d Reed relay