Replacement of vacuum control unit at injection pump

WIS 07.1-220

Job no. of flat rates or standard texts and flat rates data 07-8621.

Removal

Replacement of vacuum control unit at injection pump – rysunek

1 Unscrew vacuum control valve on injection pump.

Replacement of vacuum control unit at injection pump – rysunek

2 Remove vacuum control unit after loosening 4 fastening screws.

Installation

3 Bolt vacuum control unit to governor cover, using 2 new gaskets (1).

Make sure that connecting rod of vacuum control unit latches onto control rod.

1 Gasket 2 Steel ring