Replacement of vacuum control unit at injection pump
WIS 07.1-220
Job no. of flat rates or standard texts and flat rates data 07-8621.
Removal
1 Unscrew vacuum control valve on injection pump.
2 Remove vacuum control unit after loosening 4 fastening screws.
Installation
3 Bolt vacuum control unit to governor cover, using 2 new gaskets (1).
Make sure that connecting rod of vacuum control unit latches onto control rod.
1 Gasket 2 Steel ring