Removal and installation of injection nozzles
WIS 07.1-230
Job no. of flat rates or standard texts and flat rates data 07-6810 or 6830.
Tightening torques
Injection nozzles
Injection lines
Special tools
Box wrench socket open, 17 mm, 1/2” drive for injection lines – 000 589 68 03 00
Socket for injection nozzle 27 mm, 1/2″’ drive – 001 589 65 09 00
Conventional tools
Torque wrench 1/2” drive, 40-130 Nm
Torque wrench 1/2” drive, 15–65 Nm
Removal
1 Unscrew injection lines.
2 Detach leak-off fuel hoses and plug of 5th injection nozzle.
3 Unscrew injection nozzles using socket. If precombustion chamber collar comes undone, tighten all collars (O5—117).
4 Withdraw nozzle plate (53).
5 Sight-check precombustion chamber. Direct flashlight into chamber and examine whether ball pin is in satisfactory condition.
46 Cylinder head gasket 53 Nozzle plate
50 Collar 80 Injection nozzle
51 Precombustion chamber 81 Pin-type glow plug
52 Sealing ring
Installation
6 Install in reverse order, using new nozzle plates. Note tightening torques.