Testing injection nozzles

WIS 07.1-6712

Testing injection nozzles – rysunek
Testing injection nozzles – rysunek
Testing injection nozzles – rysunek
Testing injection nozzles – rysunek

Preceding work: Operation no. of operation texts and work units or standard texts Removing and installing injection nozzles (07.1-G830), and flat rates:

Injection nozzle (60) …… scence eee eee connect to test ter (052) 000 589 00 68 00, pump forcibly 5 times; to do this, close valve (a).

Note Only clean test oil or diesel fuel may be used for the test.

AN When testing an injection nozzle, on no account place your hand into the spray of a nozzle. The spray penetrates deeply into the skin and destroys the tissue. The fuel which gets into the bloodstream may cause blood poisoning.

eigen = RA 07.1.1621-8712/1 test by slowly operating hand lever (b), about 1 stroke per second. check; with short, rapid strokes, about 2 strokes per second, the spray rnust be ejected cleanly and in a closed pattern. A ~ stringy spray pattern „poor” B – closed spray pattern „gocd” Ejection pressure or opening pressure test by opening valve (a) and slowly operating hand lever (b) (at least 1 stroke per second). Specifications : 115+8 bar for new nozzles 110 bar for used nozzles.

Special tool

Testing injection nozzles – rysunek

Tester EFEP 60H Bosch 0/681 200 502

ete = RA 07.1.1621-6712/2