Removing and installing ARA actuator

WIS 07.1-1856

Removing and installing ARA actuator – rysunek

Operation no. of operation texts and work units or standard texts and flat rates:

A Engine 605.911 B Engine 606.910

Electrical connection at ARA actuator (Y22/3) … unplug, plug in. Bolts of ARA actuator seen remove, install. ARA actuator (Y22/3) ee eee tena remove, install.

Installation note

Electrical connection must face up.

Engine 606.910 Lift rod (41/1) in new actuators ………….. insert (see note).

All models

O-ring (41/2)… ec eee See eee ne check, replace if necessary.

cote = RA 07.1.1621 ~1856/1

Removing and installing ARA actuator – rysunek

Notes regarding replacing ARA actuator, engine 606.910 When replacing the ARA actuator, the previous lift rod (41/1) must be installed in the new actuator. This ensures that the clearance „b” is correct. If the lift rod (41/1) is faulty, the injection pump must be set on the test bench.

22/3 ARA actuator a Displacement 1.5~1.7 mm (encapsulated travel) = control travel 2.25~-2.55 mm b Clearance to full load connection 0.1–1.0 mm

PO7-6503–17

mie = RA 07.1.1621 -1856/2