Testing electronic idle speed control with/without anti-jerk control
WIS 07.1-1841
Preceding work: Operation no. of operation texts and work units or standard texts Testing, adjusting idle speed (07-2053) and flat rates: 07-1841
Engine 602.96, 603.96 with test coupling (X92 or X11/4)
Pulse counter (013) 6… eee ee eee connect to battery (G1) and to test coupling (X92). Overvoltage protection relay fuse ………… check. Engine 2.0… ec cee eee eens run at idling speed. Start button of pulse counter (013) ……….. operate for 2~4 seconds. Display 2.2.2… eee eee eee read and note. Start button 2.0… eee eee press again. If no new display appears, no further fault in system.
cotton RA 07.1.1032-1841/1
The number of pulses indicates whether and which component is faulty, or whether components in the control circuit are defective.
Assignment (X92) Jack 1 ground Jack 2 TD signal Jack 3 pulse output, ARA control unit (N8/2) Jack 4 pulse output, EDS control unit (N39) only Ca)
Only short-circuit faults are detected with control units designation ”R01”. Control units with designation ”RO2” also detect interrupts. Production breakpoint: control unit with ””RO2”, May 1988.
Pulse readout ”2” test, resistance 0.4–2.5 kM. Engine speed sensor (L3) to connector (L3x) engine idling voltage >4 V ~. Pulse readout ”3” Coolant temperature sensor (B11/1) test, specified value +20 °C 2.2–2.8 kQ
cwtiinm = RA 07.1.1032-1841/2
Pulse readout ”5” function test Raise engine speed to 1000 rpm. Operate accelerator lever briefly several TIMES ee ee ee ee eee ARA actuator clicks audibly. ARA operating. Pulse readout „6” 2-pin connector of ELR actuator (Y22) detach (for at least 3s) and fiton again ………… Engine speed increases briefly.
Special tools
Commercially available tools
Digital tester Bosch, MOT 002.02 Sun, DIT 9000
win RA 07.1.1032-1841/3
Connection diagram Connect digital tester and pulse generator.
Connect pulse counter (013) to battery (G1) and test connector (X11/4).
Note The U-batt LED in display panel must light up; if not: a) Test fuse of pulse counter b) Test jack 1 of test connector (X11/4) to battery positive (approx. 12 V) c) Test jack 4 of test connector (X11/4) to battery positive (approx. 12 V)
whom ~=RA 07.1.1032-1841/4
Test fuse in overvoltage protection relay.
Run engine at idling speed.
Operate start button of pulse counter (013) for between 2 and 4 seconds. Check readout on the display of the pulse counter (013) and note. Again press start button for between 2 and 4 seconds. If there is no other fault in the system, no new readout appears. Rectify noted faults according to test routine or perform test of components.
Note regarding pulse readout Numbers from 1 to 6 appear on the display panel of the pulse counter. The number 1 means that no fault has been detected in the electronic system. All the other numbers are assigned to a certain fault circuit.
egitim = RA 07.1.1032-1841/5
Testing components Testing overvoltage protection relay (K1/1).
anima RA 07.1.1032-1841/6
Pulse readout ”2”
wtihs = RA 07,1.1032-1841/7
apt = RA 07.1.1032-1841/8
Pulse readout „3”
wari = RA 07.1.1032-1841/9
Pulse readout 5” (function test)
ota — RA 07.1.1032-1841/10
Pulse readout ”6”
eniogn = RA 07.1.1032-1841/11
ewiann RA 07.1.1032-1841/12
Test ARA reference resis (if fitted)
ima = RA 07.1.1032~1841/13
Note The ic ition must be switched off in order to repl the reference resistor, otherwise the new resistance trimming will not be recognised. The reference resistors listed in the table can also be simulated with the resistance decade in order to determine the resistance.
agtiioyn = RA 07.1.1032-1841/14