and flat rates:

WIS 07.1-1856

ov. 1-1856 Replacing Act

and flat rates: – rysunek
and flat rates: – rysunek

Preceding work: Operation no. of operation texts and work units or standard texts and flat rates: 07-1856

Screws (6b) 2… ee eee eee wee ee eee ee §=§©6FEMOvE, install (use TORX T30). Bracket (6c) 00. c ae «+… remove, install. Actuator (Y22/3) ………00ee0eeeeeeeeee remove, install, electrical connection must point upwards. Oering (161) 22… ce ee ee eee ee ee ee eee FONOW. Lifting rod (163) 2… ec ewe ee eee eee eee — insert in new actuators.

Distinguishing features of ARA and E

and flat rates: – rysunek

actuators

A ELR actuator (red) fixed lifting rod (arrow) BARA actuator (black or grey) loose lifting rod (arrow)

eutiiys = RA 07.1.1051-1856/1

and flat rates: – rysunek

Repair instructions on renewing the ARA actuators When renewing the ARA actuators the old lifting rod (163) must be installed in the new actuators.

This ensures that the play „b” is correct. In the event of a defective lifting rod (163) the injection pump must be set on the test stand.

Electrical connection 161 O-ring 162 Lifting rod 163 ARA capsule Sliding bott 22 Retum spring Guide sleeve Y2e/y ARA actuator adjustment travel 0.9 + 1 (capsule travel) = contol rod travel 1.35–1.65 mm Play at full load connection 0.1–1.0 mm

apie = RA 07.1.1051-1856/2