and flat rates:
WIS 07.1-1856
ov. 1-1856 Replacing Act
Preceding work: Operation no. of operation texts and work units or standard texts and flat rates: 07-1856
Screws (6b) 2… ee eee eee wee ee eee ee §=§©6FEMOvE, install (use TORX T30). Bracket (6c) 00. c ae «+… remove, install. Actuator (Y22/3) ………00ee0eeeeeeeeee remove, install, electrical connection must point upwards. Oering (161) 22… ce ee ee eee ee ee ee eee FONOW. Lifting rod (163) 2… ec ewe ee eee eee eee — insert in new actuators.
Distinguishing features of ARA and E
actuators
A ELR actuator (red) fixed lifting rod (arrow) BARA actuator (black or grey) loose lifting rod (arrow)
eutiiys = RA 07.1.1051-1856/1
Repair instructions on renewing the ARA actuators When renewing the ARA actuators the old lifting rod (163) must be installed in the new actuators.
This ensures that the play „b” is correct. In the event of a defective lifting rod (163) the injection pump must be set on the test stand.
Electrical connection 161 O-ring 162 Lifting rod 163 ARA capsule Sliding bott 22 Retum spring Guide sleeve Y2e/y ARA actuator adjustment travel 0.9 + 1 (capsule travel) = contol rod travel 1.35–1.65 mm Play at full load connection 0.1–1.0 mm
apie = RA 07.1.1051-1856/2