Repairing tapped holes for transmission mounting
WIS 01-1240
Preceding work: Engine removed (01-0300)
Engine 119.960
Core hole with HSS twist drill …………… bore out (step 1). Swarf …..c eee eeeeeee blow out (step 2).
Bore (4) with oil return duct ………….00.- connect (step 2). Right cylinder head 0… ee eee eee remove, install (01-4150). OilsuMp eee eee eee eee eee remove, install (01-3100). Swarf in oil duct 0.1… 6. cee cee eee blow out from above. HELI-COIL mounting thread ………….00tap (step 3). Swarf occ eee eee ene blow out (step 4).
HELI-COIL threaded insert M10 screw in (step 5).
Insertion depth 2.0… 2. cee eee eee eee observe (step 5).
iim §=RA 01.1311-1240/1
Cf eo fom 4 5 Pe ae
Tang of HELI-COIL threaded insert ……….. break off with a drift, remove. Ease of movement of threads ………….. check (step 7). Stud boltS 2… cee ee ee eee screw into bore 1 and 4 (step 8).
Commercial tools
HELI-COIL tap M10 Art. No. 0140 0100104
HELI-COIL threaded insert M10 e. g. Ballhoff & Co. Standard Art. No. 0130 0100020 D-4800 Bielefeld 14
HELI-COIL hand installation tool M10 Art. No. 0150 0410000–1
Note Torn threads for transmission mounting should be replaced by HELI-COIL standard threaded inserts, Art. No. 0130 0100020 with a length corresponding to twice the diameter of the bolts (11 threads).
Reconditioning
1 Drill core hole approx. 27 mm deep with an 10 mm dia. HSS twist drill.
Minimum core hole diameter 10 mm, maximum 10.3 mm.
aii §=RA 01.1311-1240/2
420°! x Loose
2 Blow out swarf.
AN Bore (4) merges into oil return duct. When repairing bore (4), remove and install right cylinder head (01-4150). Remove and install oil sump (01-3100).
1 and4 M10 stud bolt 2and3 M10 thread
ZN Blow swarf from bore (4) out of oil duct from above (arrow).
3 Tap HELI-COIL mounting thread with HELICOIL M10 tap (outer diameter 12.0 mm), Art. No. 0140 0100104, approx. 25 mm deep. Lubricate tap with honing oil when performing this step.
4 Blow out swarf.
AN Bore (4, see step 2).
whim §=RA 01.1311-1240/3
5 Screw in oiled HELI-COIL M10 standard threaded insert, Art. No. 0130 0100020, with the M10 hand installation tool, Art. No. 0150 0410000-1.
AN The top thread must stop approx. 2 mm below the mating surface.
6 Break off tang of HELI-COIL threaded insert with a drift.
7 Examine inserted thread for possible misalignment and for ease of operation of threads by screwing in a bolt.
The insertion depth should be approx. 23 mm.
8 Install stud bolts (1) and (4).
A The microencapsulated stud bolt (4) seals the oil duct in the crankcase. The stud bolts lose their sealing effect after being removed. They may only be used once.
1 and 4 M10 stud bolt 2and3 M10 thread
elie §=RA 01.1311-1240/4
ee a AT A