Instructions for test and repair work
WIS 30-355
@ The plug connections of reference
potentiometer and actuator are water-tight. They may be opened only for the test work specified in the test routine.
® Cleaning agents or contact spray must not
be used on the plug connections of reference potentiometer and actuator.
e@ The electronic accelerator contro! unit is not
fuseprotected.
® Do not create a contact between connector
pins 7 and 19 of the electronic accelerator control unit.
e Before adjusting or checking the accelerator control with the ignition switched on, depress accelerator pedal as far as full throttle stop (approx. 5 seconds) to ensure that the throttle valve setpoint signal from the ABS/ASR control unit enables the full throttle position.
e Ground cables from the ABS/ASR control
unit and from the electronic accelerator control unit are connected directly to the battery ground (W10).
@ When performing welding work with an
electrical welding torch, pay attention to the following points: – Disconnect negative terminal of battery. – Connect ground terminal of welding equipment directly to the part to be welded.