Conducting fuel quantity comparative measurement

WIS 07.3-160

Conducting fuel quantity comparative measurement – rysunek

Flow meter 0.0… cece ee position horizontally next to the vehicle. Injection lines 1.0.0.2… 0… ee eee disconnect from fuel distributor and injection valves, reconnect. Clean connection fittings beforehand. Flow meter (054) 2… eee ee ee connect to fuel distributor (sequence see figure). Fuel return line 2… 2.2 ee insert in filler neck of fuel tank. Adjusting device for setting the sensor plate …. connect to stop lever of sensor plate (see figure). Relay fuel pump (N16/4) …………..000. pull off and bridge jacks 7 and 8 (see figure). Sensor plate 2… 2.2 eee deflect and press keys 1 to 8 for device bleeding one after the other. Measuring device key 1.1… ee ee ee eee press and hold. Deflect sensor plate by means of the adjusting device until an idle speed quantity of 4 cm3/min has been reached. Lock sensor plate.

rates, enter on data sheet B 20 800.99.472.00. Maximum permissible fluctuation between the cylinders 0.4 cm3/min (idle speed). Then check part and full load flow rates as described before. For this purpose deflect sensor plate. a) Part load 30 cm*/min b) Full load 100 cm?/min Maximum permissible fluctuation between cylinders: Part load 4 cm?/min Full load 10 cm?/min If the fluctuation is outside the tolerance, renew fuel distributor (07.3-205). Engine 0.0… ee eee run, check all fuel connections for leaks. Idle speed adjust (07.3-105).

Special tool

Conducting fuel quantity comparative measurement – rysunek
DesignationOrder designation
Fiow meterKDJE-P 300
Test trolley ’)M 200/2 or KDJE-W 100

1) If the test trolley is used for the flow meter, an additional angle plate is required. This can be made up or obtained from a Bosch representation.

Conducting fuel quantity comparative measurement – rysunek

Notes

The measurement should be carried out with the engine stopped. The operating condition (idle speed, part or full load) is simulated by means of an adjusting device on the sensor plate.

Conducting fuel quantity comparative measurement – rysunek

Arrangement of fuel lines to comparative fuel flow meter

Locking sensor plate with adjusting device

Model 107

Conducting fuel quantity comparative measurement – rysunek

Pull off coupling tail lamp cable harness (X18) in footwell left below floor panel. Connect terminal 2 with terminal 30 (terminal block next to overvoltage protection). The fuel pump will be supplied with voltage.

Model 126

Conducting fuel quantity comparative measurement – rysunek

Pull off fuel pump relay (N16/4) and bridge the two jacks 7 and 8 (terminals 30 and 87). The fuel pump will be supplied with voltage.