Conducting fuel quantity comparative measurement (continued)

WIS 07.3-165

Conducting fuel quantity comparative measurement (continued) – rysunek
Conducting fuel quantity comparative measurement (continued) – rysunek
Conducting fuel quantity comparative measurement (continued) – rysunek
Conducting fuel quantity comparative measurement (continued) – rysunek
Conducting fuel quantity comparative measurement (continued) – rysunek

N16/4 Fuel pump relay with kickdown cut-out X26 Connector, interior/engine x11 Diagnostic socket/terminal block (circuit TD) 003 Multimeter 026 Engine tester

Electrical wiring diagrams (07.3-128). Checking power consumption of fuel pump (07.3-130).

: Multimeter —< Jack _ Plug Bridge LL Ground “OQ Multimeter resistance measuring mode Multimeter DC voltage measuring mode

Impulse period displayTest step/ Scope of testPossible cause/Remedy
–1.0 Voltageon fuel pump relay (N16/4)pulled ONOpen circuit fuse 7, terminal 15 ground connection.
–1.4 WiringOFF pulledOpen circuit.
–42 WiringOFF = pulledOpen circuit.
413 WiringOFF K1/1 off.—Opencircuit.
–1.4 Wiringoff.OFF pulledOpen circuit.
Conducting fuel quantity comparative measurement (continued) – rysunek
Conducting fuel quantity comparative measurement (continued) – rysunek
Conducting fuel quantity comparative measurement (continued) – rysunek
Conducting fuel quantity comparative measurement (continued) – rysunek
Conducting fuel quantity comparative measurement (continued) – rysunek
Conducting fuel quantity comparative measurement (continued) – rysunek

Set value/ cause/Remedy step/ of Function

OFF pulled green

plug 02 21

engine 10-14V ground starting signal

OFF X26— <1Q
OFF off.~=9<192
pulled engine= 6–12 V
OFF pulled Fig.)<12 <1
ImpulseTest step/Possible cause/Remedy
periodScope ofTest connection Requirement Function
displaytest
Conducting fuel quantity comparative measurement (continued) – rysunek
Conducting fuel quantity comparative measurement (continued) – rysunek
Conducting fuel quantity comparative measurement (continued) – rysunek

– 4.0 X26 as Wiring

Kickdown required shutoff

engine

up to

the governed (approx.

–4.1 WiringOFF X26Open circuit.
–4.2 WiringOFF $16/7Open circuit. Kickdown switch (S16/7) solenoid valve automatic transmission (Y3).
–5.0 Maximum governed speedengine increaseCheck TD/TN signal (test step 3.0) Renew relay (N16/4).
Conducting fuel quantity comparative measurement (continued) – rysunek

Commercially available tools: Multimeter

Engine tester

Function

The fuel pump relay has the following functions:

e@ Brief voltage supply of the fuel pumps when

switching on the ignition.

e Voltage supply of the fuel pumps during starting and with running engine. With CAT, additional voltage supply of the oxygen sensor heating.

e Switching off the fuel pumps when reaching

the maximum engine speed (speed limitation).

e Switching off the fuel pumps as soon as no more impulses are emitted via terminal TD/TN of the ignition control unit.

e@ Kickdown shutoff (test see 07.3-167).

e@ Starting valve activation (test see 07.3-126).

On vehicles with ASR the voltage to the fuel pump relay (N16/4, terminal 15) is supplied via the safety circuit from the electronic accelerator pedal (see 30-350 section E).

A Terminal 15 is not short-circuit proof to ground (see Checking electronic accelerator 30-365). On some versions the jack 1 (terminal V) on the fuel pump relay coupling is occupied. No plug pin is available for this on the fuel pump relay, which is why it is without function.

Fuel pump relay (N16/4)

The function in the fuel pump relay was increased by a separate oxygen sensor heating in two stages:

1st version up to approx. 12/89

The fuel pump relay is equipped with an additional plug for the oxygen sensor heater with the designation 87H. This also resulted in a change of the wiring connection on the relay. The activation is the same as before, as the additional plug 87H is connected with the plug of designation 87 by means of a bridge.

2nd version as of 01/90

From this time, the bridge between terminals 87 and 87H is no longer required. For this purpose the control electronics in the relay have been changed. The switch-on temperature for the oxygen sensor heating is +20 °C and is determined by the coolant temperature sensor.

Note Only the new fuel pump relays are available as parts. This means that on vehicles prior to 09/89 the activation of fuel pump and oxygen sensor heating is still effected by plug 87. The plug 87H remains without function on these vehicles.

Arrangement

Conducting fuel quantity comparative measurement (continued) – rysunek

Model 107

The fuel pump relay N16/4 is arranged behind the glove compartment. The glove compartment must be removed for tests. Disengage the relay plug holder.

Conducting fuel quantity comparative measurement (continued) – rysunek

In part of the vehicles it is possible to remove a flap in the glove compartment base.

Model 126

The fuel pump relay N16/4 is arranged in the unit compartment left.