Conducting fuel quantity comparative measurement (continued)
WIS 07.3-165
N16/4 Fuel pump relay with kickdown cut-out X26 Connector, interior/engine x11 Diagnostic socket/terminal block (circuit TD) 003 Multimeter 026 Engine tester
Electrical wiring diagrams (07.3-128). Checking power consumption of fuel pump (07.3-130).
: Multimeter —< Jack _ Plug Bridge LL Ground “OQ Multimeter resistance measuring mode Multimeter DC voltage measuring mode
| Impulse period display | Test step/ Scope of test | Possible cause/Remedy | ||||
| – | 1.0 Voltageon fuel pump relay (N16/4) | pulled ON | Open circuit fuse 7, terminal 15 ground connection. | |||
| – | 1.4 Wiring | OFF pulled | Open circuit. | |||
| – | 42 Wiring | OFF = pulled | Open circuit. | |||
| 413 Wiring | OFF K1/1 off. | — | Opencircuit. | |||
| – | 1.4 Wiring | off. | OFF pulled | Open circuit. |
Set value/ cause/Remedy step/ of Function
OFF pulled green
plug 02 21
engine 10-14V ground starting signal
| OFF X26 | — <1Q |
| OFF off. | ~=9<192 |
| pulled engine | = 6–12 V |
| OFF pulled Fig.) | <12 <1 |
| Impulse | Test step/ | Possible cause/Remedy | |
| period | Scope of | Test connection Requirement Function | |
| display | test | ||
– 4.0 X26 as Wiring
Kickdown required shutoff
engine
up to
the governed (approx.
| – | 4.1 Wiring | OFF X26 | Open circuit. |
| – | 4.2 Wiring | OFF $16/7 | Open circuit. Kickdown switch (S16/7) solenoid valve automatic transmission (Y3). |
| – | 5.0 Maximum governed speed | engine increase | Check TD/TN signal (test step 3.0) Renew relay (N16/4). |
Commercially available tools: Multimeter
Engine tester
Function
The fuel pump relay has the following functions:
e@ Brief voltage supply of the fuel pumps when
switching on the ignition.
e Voltage supply of the fuel pumps during starting and with running engine. With CAT, additional voltage supply of the oxygen sensor heating.
e Switching off the fuel pumps when reaching
the maximum engine speed (speed limitation).
e Switching off the fuel pumps as soon as no more impulses are emitted via terminal TD/TN of the ignition control unit.
e@ Kickdown shutoff (test see 07.3-167).
e@ Starting valve activation (test see 07.3-126).
On vehicles with ASR the voltage to the fuel pump relay (N16/4, terminal 15) is supplied via the safety circuit from the electronic accelerator pedal (see 30-350 section E).
A Terminal 15 is not short-circuit proof to ground (see Checking electronic accelerator 30-365). On some versions the jack 1 (terminal V) on the fuel pump relay coupling is occupied. No plug pin is available for this on the fuel pump relay, which is why it is without function.
Fuel pump relay (N16/4)
The function in the fuel pump relay was increased by a separate oxygen sensor heating in two stages:
1st version up to approx. 12/89
The fuel pump relay is equipped with an additional plug for the oxygen sensor heater with the designation 87H. This also resulted in a change of the wiring connection on the relay. The activation is the same as before, as the additional plug 87H is connected with the plug of designation 87 by means of a bridge.
2nd version as of 01/90
From this time, the bridge between terminals 87 and 87H is no longer required. For this purpose the control electronics in the relay have been changed. The switch-on temperature for the oxygen sensor heating is +20 °C and is determined by the coolant temperature sensor.
Note Only the new fuel pump relays are available as parts. This means that on vehicles prior to 09/89 the activation of fuel pump and oxygen sensor heating is still effected by plug 87. The plug 87H remains without function on these vehicles.
Arrangement
Model 107
The fuel pump relay N16/4 is arranged behind the glove compartment. The glove compartment must be removed for tests. Disengage the relay plug holder.
In part of the vehicles it is possible to remove a flap in the glove compartment base.
Model 126
The fuel pump relay N16/4 is arranged in the unit compartment left.