Checking choke system

WIS 07.3-125

Test values

System pressure at idle with engine cold or at operating temperature 5.0–5.6 bar gauge pressure

3.4–3.8 bar gauge pressure Warm-up compensator at 530 mbar ’) stabilized Control pressure at idle with a engine at operating temperature Full load enrichment at idle 2.8–3.2 bar gauge pressure (vacuum hose pulled off)

Control pressure according to ambient temperature min. 0.5 bar gauge pressure (refer to diagram) at idle with engine cold

Starting voltage 10 volts

1 ) If control pressure is not attained, check intake manifold vacuum (refer to section ‘‘Checking control pressure at idle with engine at operating temperature’’).

Special tool

Checking choke system – rysunek

Pressure measuring device

Conventional tools

Voltmeter and ohmmeter

Revolution counter

Checking

1 Pull off cable plug on warm-up compensator and on cold starting valve.

2 Starting voltage

Check voltmeter while paying attention to polarity on battery.

Pull cable 4 from ignition coil. Actuate starter for a short moment while reading voltage. Nominal value 10 Volts. If the nominal value is not attained, check battery, charge or renew, if required.

3 Check air flow sensor plate and control piston for easy operation, fuel pressures and for internal leaks, as well as breakaway time of warm-up compensator (07.3~—120).

Checking cold-starting valve for function and leaks

Checking choke system – rysunek

5 Remove cold-starting valve (98) with fuel line connected.

6 Hold cold-starting valve into a container.

Checking function

7 Switch-on ignition.

8 Connect cold-starting valve with separate cable to B+ and ground. Cold-starting valve should eject in cone shape.

Attention! Connect cable first to cold-starting valve to avoid sparking.

No separate cable is required below + 15° C, attach cable plug instead and pull cable plug from safety switch.

Checking for leaks

9 Loosen separate cable connection on cold-starting valve. Dry cold-starting valve at nozzle. No drops should show up.

10 Switch-off ignition.

11 Mount cold-starting valve with new seal.

12 Return cable plug to safety switch and coldstarting valve.

Checking choke system – rysunek

Checking thermo-time switch

The cold-starting valve is actuated only at coolant termperatures below +15° C by means of closed thermotime switch.

The actuating time increases with decreasing temperature and attains approx. 12 seconds at —20°C.

Testing below + 15° C coolant temperature

13 Connect voltmeter to connection of cold-starting valve.

14 Actuate starter. Voltmeter should then indicate

10 Volts for a given time, depending on coolant temperature.

The switching time increases with decreasing temperature by approx. 1.5 seconds per 5°C.

e.g. +15 =0 seconds + 10° = 1.5 seconds

During this test, it is recommended to check thermotime switch also with an ohmmeter.

Test value below + 15° C:

Connection G-ground = approx. 48 2 Connection W-ground = approx. 02 (Contacts in switch closed).

Test above + 15° C coolant temperature

Above + 15° C coolant temperature, the thermo-time switch can be tested with an ohmmeter only. For this purpose, pull plug from thermo-time switch.

Test value above + 15 °C:

Checking choke system – rysunek

Connection G-ground = approx. 62 2 Connection W-ground = approx. 270 2 (Contacts in switch opened).

Put back plug.

98 Cold starting valve 99 Thermo time switch C To terminal 50

Checking switch-off point of supplementary air valve

19 The engine speed should be 800—1000/min immediately upon cold start. The speed will then increase to approx. 1200—1300/min and will return to normal idling speed at approx. 70 °C coolant temperature.

20 Connect fuel Jines, run engine once again and check all fuel connections for leaks.