Testing contact (breaker) controlled transistorized ignition

WIS 07.5-520

Conventional tools

1 voltmeter; measuring range O—3 V, O—15 V with 0.1 V scale graduation

1 ohmmeter, measuring range starting 0.1 ohm

1. Testing series resistances

Loosen line connection on one connection of resistance to be tested.

Measure resistance with ohmmeter.

Series resistance Resistance nominal value at + 20°C

0.4 ohm 0.4 + 0.05 ohm 0.6 ohm 0.6 + 0.05 ohm

For warmer series resistances, the measured values are slightly higher.

2. Testing ignition coil

Insulation test

Separate ignition coil by removing terminals 1, 15, 4 from vehicle supply system.

Connect engine tester to ignition coil. Test according to operating instructions.

Whenever possible, test ignition coil with a suitable engine tester (e.g. SUN 745 or 1130) under operating conditions. The discovered faults are above all insulation damage, grounding and interturn shorts.

Evaluate voltage flow on scope according to subsequent illustration.

Testing contact (breaker) controlled transistorized ignition – rysunek
Testing contact (breaker) controlled transistorized ignition – rysunek

20-

Display Line-up Fault Voltage below 20 kV, less than 8 voltage peaks Cause Interturn interruption, interturn short or insulation damage against ground Remedy Renew ignition coil

Display evaluation

The ignition is perfect when the first oscillation attains 20 kV and at least 8 voltage peaks will follow. If this value is not attained, replace ignition coil.

Resistance test

Resistance nominal value at + 20°C
Primary winding measured between terminal 1 and 150.38–0.45 ohm
Secondary winding measured between terminal 1 and 48–11 kQ

Measurements will be slightly higher when ignition coil is warmer.

3. Testing contact breaker point

For perfect function of transistorized systems the transfer resistance on contact breaker point should not be too high. To check, measure voltage drop on closed contact breaker point.

Connect voltmeter: + to cable connector (= terminal 7 or TD on switchgear) — to ground

Voltage indication max 0.3 volt.

If this value is exceeded, install a new contact breaker.

4. Testing switchgear and line connections

Check whether switchgear is connected to voltage or whether, if pertinently contacted, the switching transistor will lock the primary current of the ignition coil or let it pass. The primary current is not directly measured but, for the sake of simplicity, the voltage drop caused by this current.

Test with engine stopped and ignition switched on.

Test voltage drop at input of 0.4 ohm resistance with

contact braker point closed.

Connect voltmeter: + to input series resistance 0.4 ohm — to ground

The voltage drop may amount to max 0.4 volt.

When voltage drop is too high, check cable and cable connections.

4.1 Ge switchgear

Check connections on series resistances, on cable connector and on ignition coil for perfect condition.

Voltage with breaker point opened

This will check the locking conduct of transistor.

Connect voltmeter: + to terminal 15 ignition coil — to ground

No voltage should be available at terminal 15 ignition coil, i.e. readout = 0 volt.

If readout is not O volt, the transistor in switchgear is no longer locking. Replace switchgear.

Voltage with breaker point closed

Voltmeter connected as before.

Voltage at terminal 15 ignition coil = 2.6–3.5 volts.

If not, transistor is no longer switching through. Replace switchgear.

With breaker point closed or opened, the voltage measured at terminal 1 of ignition coil amounts to 0 volt.

If these values are above or below 0 volt, test series resistances, ignition coil and cables.

4.2 Ge or Si switchgear — wheel house unit —

in model 107

Designation of 4-core connecting line on switchgear

brown. …. ground black…… terminal 16 to series resistance 0.6 ohm

red/black . . . terminal 15 to series resistance 0.4 ohm

green/yellow . terminal 7 to cable connector ter-

minal 1 — ignition

distributor

Check connections on series resistances, on cable connector and on ignition coil for perfect condition.

Voltages with breaker points opened

This will check the locking conduct of transistor.

Connect voltmeter: + to terminal 15 ignition coil — to ground

There should be no voltage at terminal 15 ignition coil, i.e. readout = 0 volt.

If readout is not 0 volt, the transistor in switchgear is no longer locking. Replace switchgear.

Voltage with breaker point closed

Voltmeter connected as before.

Voltage on terminal 15 ignition coil = 2.6–3.5 volts.

if not, the transistor in switchgear is no longer switching through. Replace switchgear.

Voltage on terminal 1 of ignition coil with breaker point closed or opened amounts to 0 volt.

\f these values are below or above specifications, check series resistances, ignition coil and cables.

4.3 Si switchgear

Checking line connections

Check connections on series resistances, on cable connector and on ignition coil for perfect condition. With the ignition switched on, the pulled off 3-pole plug of switchgear plug connection should be connected to battery voltage at terminals 15 and 16.

Connect voltmeter: + to terminal 15 or 16 — to ground

Voltage with breaker point opened

This will check the locking conduct of the transistor.

Connect voltmeter: + to terminal 15 ignition coil — to ground

Terminal 15 ignition coil should carry battery voltage. If not, transistors in switchgear are no longer locking. Replace switchgear.

Voltages with breaker point closed

Voltmeter connected as before.

Voltage on terminal 15 ignition coil = 8.2–9.6 volts.

With breaker point closed, voltage on terminal 1 of ignition coil is 4.8–6.3 volts; with breaker point opened, battery voltage.

If not, transistors are no longer switching through. Replace switchgear.

4.4 Standard switchgear (Si)

Inspection of line connections

Pull 4-pole connecting plug from switchgear and test with voltmeter for battery voltage at 4-point round plug terminal 15 and terminal 16 with ignition switched on.

Connect voltmeter: + 1x to terminal 15 and 1 x to terminal 16

— to ground

\f there is no voltage, test all connections from input 0.4 ohm resistance to switchgear.

Then put back 4-point round plug on switchgear.

Voltage with breaker point opened

This will check the locking conduct of the transistor.

Connect voltmeter: + to terminal 1 ignition coil

— to ground

Terminal 1 should carry battery voltage.

If not, replace switchgear.

Voltage with breaker point closed

Voltmeter connected as before.

Voltage on terminal 1 ignition coil = 0.7–1.5 volts.

With breaker point closed, 3.6–4.6 volts are measured on terminal 15 of ignition coil; with breaker point opened, battery voltage.

If not, replace switchgear.

Values for testing switchgear

Testing contact (breaker) controlled transistorized ignition – rysunek

Measuring points and associated voltages for transistorized (TSZ) systems

Voltmeter Voltages outside nominal range: voltages Si standard causes, remedies Si-TSZ TSZ Plus to Minus to

battery voltageWith correct battery voltage: Excessive voltage drop battery ohm series resistance caused resistances (corrosion), line etc.
battery voltageWith correct voltage at 0.4 resistance: parallel resistance interruption between 0.4 ohm resistance input and terminal terminal 16
Higher voltage: transfer resistance breaker point too high. Renew breaker point.
8.2-96V3.6-46VWith correct voltage at switchgear terminal 7 or TD:
battery voltageSwitchgear defective
4.8–6.3V battery voltage0.7–1.5VRenew switchgear
Testing contact (breaker) controlled transistorized ignition – rysunek

Layout of individual components

Model 108.057/058, 109.056, 111.026/027

Testing contact (breaker) controlled transistorized ignition – rysunek

2 Series resistance 0.4 ohm 4 Series resistance 0.6 ohm 5 Ignition coil

3 Switchgear 5 Ignition coil 7 Cable connector

Testing contact (breaker) controlled transistorized ignition – rysunek

Model 107

Testing contact (breaker) controlled transistorized ignition – rysunek

1. Ignition coil 2 Series resistance 0.6 ohm 3 Series resistance 0.4 ohm 4 Cable connector 5 Line from switchgear

Model 108.067/068 , 109.057

Testing contact (breaker) controlled transistorized ignition – rysunek

1 Switchgear 2 Cable connector

Testing contact (breaker) controlled transistorized ignition – rysunek

1. Ignition coil 2 Series resistance 0.4 ohm 3 Series resistance 0.6 ohm

Testing contact (breaker) controlled transistorized ignition – rysunek

Switchgear layout model 107