Draining and filling-in of coolant — anti-freeze table

WIS 20-010

Tightening torques

Drain plug radiator

Mixing ratio of anti-freeze!) and water”)

Anti-freeze/water in liters on types Anti-freeze up to 107.023 107.024 107.043 107.044 116.028 116.032 116.029 116.033

—30 °C 6.25/7.75 6.75/8.25 —40 °C 7.25/6.75 7.75/7.25

Total capacity in liters

14 15

1) Refer to specifications for service products sheet 310. 2) Refer to specifications for service products sheet 325.

Conventional tool

Draining and filling-in of coolant — anti-freeze table – rysunek

Anti-freeze tester Prestone VU-Check (Union Carbide) e.g. Philipp Gather, D—4020 Mettmann 2

R-4789

Note To prevent corrosion, concentration of anti-freeze should not drop below —20 °C (30 % by volume).

If no anti-freeze is available and only water is filledin be sure to add 1 % treating compound (anticorrosion oil, 10 cc/1 water).

Draining and filling-in of coolant — anti-freeze table – rysunek

Draining

1 Open cap on expansion tank or radiator in steps (only below 90 °C).

Draining and filling-in of coolant — anti-freeze table – rysunek
Draining and filling-in of coolant — anti-freeze table – rysunek

2 Unscrew drain plugs on radiator as well as on both sides of cylinder crankcase.

Filling-in

3 Set both heater levers to position ‘warm’.

4 Fill-in coolant slowly.

On vehicles with expansion tank made of brass up to approx. 4 cm below sealing surface on radiator cap.

On vehicles with expansion tank made of transparent plastics up to mark shown on tank.

Draining and filling-in of coolant — anti-freeze table – rysunek

On vehicles without expansion tank to recess in upper radiator tank.

5 Run engine warm under pulsating acceleration and with radiator cap closed starting at 60 °C until thermostat opens.

6 Check coolant level and top up until specified level is attained.

Attention! Open radiator cap only below 90 °C coolant temperatur: