Draining and filling-in of coolant — anti-freeze table
WIS 20-010
Tightening torques
Drain plug radiator
Mixing ratio of anti-freeze!) and water”)
Anti-freeze/water in liters on types Anti-freeze up to 107.023 107.024 107.043 107.044 116.028 116.032 116.029 116.033
—30 °C 6.25/7.75 6.75/8.25 —40 °C 7.25/6.75 7.75/7.25
Total capacity in liters
14 15
1) Refer to specifications for service products sheet 310. 2) Refer to specifications for service products sheet 325.
Conventional tool
Anti-freeze tester Prestone VU-Check (Union Carbide) e.g. Philipp Gather, D—4020 Mettmann 2
R-4789
Note To prevent corrosion, concentration of anti-freeze should not drop below —20 °C (30 % by volume).
If no anti-freeze is available and only water is filledin be sure to add 1 % treating compound (anticorrosion oil, 10 cc/1 water).
Draining
1 Open cap on expansion tank or radiator in steps (only below 90 °C).
2 Unscrew drain plugs on radiator as well as on both sides of cylinder crankcase.
Filling-in
3 Set both heater levers to position ‘warm’.
4 Fill-in coolant slowly.
On vehicles with expansion tank made of brass up to approx. 4 cm below sealing surface on radiator cap.
On vehicles with expansion tank made of transparent plastics up to mark shown on tank.
On vehicles without expansion tank to recess in upper radiator tank.
5 Run engine warm under pulsating acceleration and with radiator cap closed starting at 60 °C until thermostat opens.
6 Check coolant level and top up until specified level is attained.
Attention! Open radiator cap only below 90 °C coolant temperatur: