Installation and centering of intermediate flange

WIS 01-220

Data

Radial runout of intermediate flange max. 0.10

Permissible axial runout of intermediate flange when mounted in crankshaft bearing basic bore during 0.10 one full turn.

Tightening torques Nm

Intermediate flange mounting bolts 65

Torque pressure 40 Drive plate and flywheel expansion bolt ~ Torque angle 90-—-100°

Special tool

LDial gage holder (two required) – 121 589 00 21 00

Self-made tool

Threaded pin see fig, point 3

Conventional tool

Dial gauge A 1 DIN 878 e.g. made by Mahr, 7300 Esslingen order no, 810

Note

Installation and centering of intermediate flange – rysunek

A replaced intermediate flange must be centered. The automatic transmission W4A040 requires the intermediate flange (1) with fitted pin and all-around centering system, which can be used as a replacement for the formerly used intermediate flange (2) with all-around centering system.

1 Modified intermediate flange 110011 15 45 2 Former intermediate flange 115 011 11 45 ios EE

Series installation of intermediate flange 110 011 15 45 starting end of november 1979

Starting engine end no. Starting chassis end no.

110.923 —10-014 453 = 123.030—-028 448 —12-017 710 123.050–003 543

110.984 ~19-021092 = 123.033–067 904 —12-070620 123.053–018 127

110.922 —!0-040 775 ~12–067 894 446 920-121 410 110.932 ~10-010 365 —12–002 796

110.985 ~19-014 287 4146 924/025–154 967 —12-073 060

110.986 ~19-003 392 107.042–007 301 ~—12–007 701 107.022–007 921

Installing and centering

1 Place intermediate flange over dowel pins in crankcase.

2 Tighten the four mounting bolts slightly.

Installation and centering of intermediate flange – rysunek

3 Screw threaded bolt (self-made) into crankshaft and counterlock with hex nut.

1 Hex nutM 12x 1.5 2 Threaded bolt 10 mm dia 3 Hex nutM10x 1

Installation and centering of intermediate flange – rysunek

4 Attach dial gauge holder with dial gauge to threaded bolt.

5 Position feeler pin at fitting point of centering surface. Set dial gauge to 0.

Installation and centering of intermediate flange – rysunek

6 Rotate crankshaft for one full turn by means of tool combination. Vertical runout should not exceed max 0.10 mm.

Note: When rotating crankshaft, make sure that the feeler pin of the dial gauge is not getting stuck.

GN BA0Rey

7 Correct vertical runout by light blows against intermediate flange.

8 Tighten fastening screws.

Note: If the vertical runout exceeds 0.10 mm, remove intermediate flange.

9 Increase diameter of both fitted bores in intermediate flange to 12.1 mm.

10 Repeat item 1-8.