Installation and centering of intermediate flange
WIS 01-220
Data
Radial runout of intermediate flange max. 0.10
Permissible axial runout of intermediate flange when mounted in crankshaft bearing basic bore during 0.10 one full turn.
Tightening torques Nm
Intermediate flange mounting bolts 65
Torque pressure 40 Drive plate and flywheel expansion bolt ~ Torque angle 90-—-100°
Special tool
LDial gage holder (two required) – 121 589 00 21 00
Self-made tool
Threaded pin see fig, point 3
Conventional tool
Dial gauge A 1 DIN 878 e.g. made by Mahr, 7300 Esslingen order no, 810
Note
A replaced intermediate flange must be centered. The automatic transmission W4A040 requires the intermediate flange (1) with fitted pin and all-around centering system, which can be used as a replacement for the formerly used intermediate flange (2) with all-around centering system.
1 Modified intermediate flange 110011 15 45 2 Former intermediate flange 115 011 11 45 ios EE
Series installation of intermediate flange 110 011 15 45 starting end of november 1979
Starting engine end no. Starting chassis end no.
110.923 —10-014 453 = 123.030—-028 448 —12-017 710 123.050–003 543
110.984 ~19-021092 = 123.033–067 904 —12-070620 123.053–018 127
110.922 —!0-040 775 ~12–067 894 446 920-121 410 110.932 ~10-010 365 —12–002 796
110.985 ~19-014 287 4146 924/025–154 967 —12-073 060
110.986 ~19-003 392 107.042–007 301 ~—12–007 701 107.022–007 921
Installing and centering
1 Place intermediate flange over dowel pins in crankcase.
2 Tighten the four mounting bolts slightly.
3 Screw threaded bolt (self-made) into crankshaft and counterlock with hex nut.
1 Hex nutM 12x 1.5 2 Threaded bolt 10 mm dia 3 Hex nutM10x 1
4 Attach dial gauge holder with dial gauge to threaded bolt.
5 Position feeler pin at fitting point of centering surface. Set dial gauge to 0.
6 Rotate crankshaft for one full turn by means of tool combination. Vertical runout should not exceed max 0.10 mm.
Note: When rotating crankshaft, make sure that the feeler pin of the dial gauge is not getting stuck.
GN BA0Rey
7 Correct vertical runout by light blows against intermediate flange.
8 Tighten fastening screws.
Note: If the vertical runout exceeds 0.10 mm, remove intermediate flange.
9 Increase diameter of both fitted bores in intermediate flange to 12.1 mm.
10 Repeat item 1-8.