Checking, replacing and tightening conrod bolts

WIS 03-310

Conrod bolt sizes

Distance Expansion stem Min. Version Part Number aandb Thread dia. d dia. c when new Expansion (fig., point 1) (fig., point 1) stem dia. a b

1st version 110 038 01 71 3 5.5 2nd version 110 038 03 71 M 10×1 8.4–0.1 8.0 4.5 3rd version 1100380471 66

Conrod bolt installation pressure 45000 N

Conrod nut torque

Initial torque 40–50

Torque angle 90–100°

Self-made tool

Steel plate see fig., point 3

Checking, replacing and tightening conrod bolts – rysunek

Checking

1 Measure smallest expansion stem diameter before reusing.

Checking, replacing and tightening conrod bolts – rysunek

Note: If the minimum expansion stem diameter reaches or is less than 8.0 mm, replace conrod bolt.

Only knock out a conrod bolt to replace it.

Checking, replacing and tightening conrod bolts – rysunek

Use third version conrod bolts for repairs.

Replacing

2 Knock out conrod bolts.

3 Press new bolts into conrod with a pressure of about 45000 N, or knock in with a hammer and mandrel.

Place the connecting rod on a ground steel plate when knocking in or pressing in conrod bolts.

Distance between holes a = 64.6 mm Bore b = 11 mm

Tightening

Checking, replacing and tightening conrod bolts – rysunek

4 Lubricate nuts and threads.

5 Tighten conrod nuts to a torque pressure of 40—50 Nm and a torque angle of 90—100°.

Attention! Tighten conrod bolts knocked in with a hammer to a torque pressure of 6(0–70 Nm and a torque angle of 90–100° for the first time.

Make sure that this instruction is observed, since otherwise the nuts of the conrod bolts may become loose.

Note: If no angle of rotation wrench is available, the connecting rod nuts can also be tightened by means of anormal socket wrench with toggle in one step by an angle of 90–100°. Estimate angle as accurately as

possible. To eliminate angle faults, do not use a torque

wrench for tightening according to angles of rotation.