Checking, replacing and tightening conrod bolts
WIS 03-310
Conrod bolt sizes
Distance Expansion stem Min. Version Part Number aandb Thread dia. d dia. c when new Expansion (fig., point 1) (fig., point 1) stem dia. a b
1st version 110 038 01 71 3 5.5 2nd version 110 038 03 71 M 10×1 8.4–0.1 8.0 4.5 3rd version 1100380471 66
Conrod bolt installation pressure 45000 N
Conrod nut torque
Initial torque 40–50
Torque angle 90–100°
Self-made tool
Steel plate see fig., point 3
Checking
1 Measure smallest expansion stem diameter before reusing.
Note: If the minimum expansion stem diameter reaches or is less than 8.0 mm, replace conrod bolt.
Only knock out a conrod bolt to replace it.
Use third version conrod bolts for repairs.
Replacing
2 Knock out conrod bolts.
3 Press new bolts into conrod with a pressure of about 45000 N, or knock in with a hammer and mandrel.
Place the connecting rod on a ground steel plate when knocking in or pressing in conrod bolts.
Distance between holes a = 64.6 mm Bore b = 11 mm
Tightening
4 Lubricate nuts and threads.
5 Tighten conrod nuts to a torque pressure of 40—50 Nm and a torque angle of 90—100°.
Attention! Tighten conrod bolts knocked in with a hammer to a torque pressure of 6(0–70 Nm and a torque angle of 90–100° for the first time.
Make sure that this instruction is observed, since otherwise the nuts of the conrod bolts may become loose.
Note: If no angle of rotation wrench is available, the connecting rod nuts can also be tightened by means of anormal socket wrench with toggle in one step by an angle of 90–100°. Estimate angle as accurately as
possible. To eliminate angle faults, do not use a torque
wrench for tightening according to angles of rotation.