Synchronizing idle speed systems
Identification: Information plate in national language on cross member in front of radiator or on cylinder head cover. Adjust engines according to data of respective emission control information plate.
Testing and adjusting values
Idle speed 1/min National version Idle speed emission value % CO
up to 1976 max. 1.5 G8 8 GOGO O 1976 max. 1.0 without air injection 1976
1973 up to 1.5 1974 Federal
6–8 without air injection 1974 California
max. 1.0 without air injection 1975/76
Special tools Oil telethermometer – 116 589 27 21 00
= Digital tester ST Connecting cable Intermediate plug (adaptor) – 000 589 72 63 00
000 589 71 6300 Trigger – 000 589 04 90 00
Conventional tools
Rpm and CO measuring instrument
Synchronizing
1 Connect test instruments. Run engine oil temperature to 60—80 °C.
2 Remove air filter.
3 Check idle speed and adjust with adjusting screw (68), if required.
4 Check idle speed emission value without air injection. For this purpose, make air injection inoperative as follows (for 1973/74 nothing need be made inoperative):
CG) 1976
Pull off blue/purple vacuum line at connecting point (arrow).
CG) 1976, model 114
Pull rubber cap (arrow) from blue/purple vacuum line.
CG) 1976, model 116
Pull rubber cap (arrow) from blue/purple vacuum line.
@sd) California 1974
Pull off red vacuum line at connecting point (arrow).
Gs) 1975/76
Pull off blue/purple vacuum line at connecting point (arrow).
The exhaust gas for idle speed CO measurement on vehicles with catalyst, (31976 and @s)1975/76, is drawn off in front of catalyst at check valve (arrow) of air injection.
For measuring idle speed emissions, open valve plate of check valve by means of a self-made wire hook. Connect exhaust gas hose of CO measuring instrument to check valve.
5 Adjust idle speed emission value without air injection. For this purpose, adjust both adjusting screws (arrows) uniformly.
Screwing out = richer
Screwing in leaner
Accelerate for a short moment, check idle speed and idle speed emission value once again and readjust, if required.
6 Check for uniform adjustment (synchronization) of mixture adjusting screws (arrows).
For this purpose, insert test wire of 0.5 mm dia. (arrow) into both air correction nozzles (78) one after the other and measure CO increase. CO increase
should be uniformly high on both sides. Readjust
with mixture adjusting screws, if required.
Note: To prevent measuring faults, do not insert test wire deeper than 10 mm into idle speed jet. Without test wire the max. idle speed emission value must not be exceeded.
Then check whether the max. permissible idle speed emission value is not exceeded without test wire and uniformly adjust both mixture adjusting screws, if required.
7 Reattach vacuum hose for air injection (air injection operating). The idle speed emission value should now be below the previously set value.