Synchronizing idle speed systems

Identification: Information plate in national language on cross member in front of radiator or on cylinder head cover. Adjust engines according to data of respective emission control information plate.

Testing and adjusting values

Idle speed 1/min National version Idle speed emission value % CO

up to 1976 max. 1.5 G8 8 GOGO O 1976 max. 1.0 without air injection 1976

1973 up to 1.5 1974 Federal

6–8 without air injection 1974 California

max. 1.0 without air injection 1975/76

Special tools Oil telethermometer – 116 589 27 21 00

= Digital tester ST Connecting cable Intermediate plug (adaptor) – 000 589 72 63 00

000 589 71 6300 Trigger – 000 589 04 90 00

Conventional tools

Synchronizing idle speed systems – rysunek

Rpm and CO measuring instrument

Synchronizing

1 Connect test instruments. Run engine oil temperature to 60—80 °C.

2 Remove air filter.

Synchronizing idle speed systems – rysunek

3 Check idle speed and adjust with adjusting screw (68), if required.

4 Check idle speed emission value without air injection. For this purpose, make air injection inoperative as follows (for 1973/74 nothing need be made inoperative):

CG) 1976

Pull off blue/purple vacuum line at connecting point (arrow).

CG) 1976, model 114

Synchronizing idle speed systems – rysunek

Pull rubber cap (arrow) from blue/purple vacuum line.

Synchronizing idle speed systems – rysunek

CG) 1976, model 116

Pull rubber cap (arrow) from blue/purple vacuum line.

Synchronizing idle speed systems – rysunek

@sd) California 1974

Pull off red vacuum line at connecting point (arrow).

Gs) 1975/76

Pull off blue/purple vacuum line at connecting point (arrow).

Synchronizing idle speed systems – rysunek
Synchronizing idle speed systems – rysunek

The exhaust gas for idle speed CO measurement on vehicles with catalyst, (31976 and @s)1975/76, is drawn off in front of catalyst at check valve (arrow) of air injection.

For measuring idle speed emissions, open valve plate of check valve by means of a self-made wire hook. Connect exhaust gas hose of CO measuring instrument to check valve.

Synchronizing idle speed systems – rysunek

5 Adjust idle speed emission value without air injection. For this purpose, adjust both adjusting screws (arrows) uniformly.

Screwing out = richer

Screwing in leaner

Accelerate for a short moment, check idle speed and idle speed emission value once again and readjust, if required.

Synchronizing idle speed systems – rysunek

6 Check for uniform adjustment (synchronization) of mixture adjusting screws (arrows).

Synchronizing idle speed systems – rysunek

For this purpose, insert test wire of 0.5 mm dia. (arrow) into both air correction nozzles (78) one after the other and measure CO increase. CO increase

should be uniformly high on both sides. Readjust

with mixture adjusting screws, if required.

Note: To prevent measuring faults, do not insert test wire deeper than 10 mm into idle speed jet. Without test wire the max. idle speed emission value must not be exceeded.

Then check whether the max. permissible idle speed emission value is not exceeded without test wire and uniformly adjust both mixture adjusting screws, if required.

7 Reattach vacuum hose for air injection (air injection operating). The idle speed emission value should now be below the previously set value.