Replacing oxygen sensor
WIS 07.3-5303
Operation No. of operation texts and work units or standard texts and flat rates:
remove, install.
Note @ = Turn union nut to the left as far as stop ~ to open ® = Turn union nut to the right as far as stop ~ to secure Splash water plate (114) ……….. sees pull off, fit on; open side should face to the rear. Oxygen sensor (G3/2) ………..0. sees unscrew with ring wrench socket 000 589 71 03 00, screw in.
Installation instruction Coat thread of oxygen sensor (G3/2) with hot lubricating paste, Part No. 000 989 76 51. Tightening torque 50 — 60 Nm as reference value. Lambda control ……. wet eee sees check, set (see Diagnosis Manual Engine, Volurne 1).
auttahij
RA 07.3.1212-5303/1
CIS-E control unit fault memory …….. see read out, erase if necessary (see Diagnosis Manual Engine, Volume 2, Index 0).
Note Stored faults which may originate from test work resulting from cables being disconnected or from a simulation, must be erased in the fault memory after completing the work.
Special tool – 000 589 71 03 00
owhhye §=RA 07.3.1212-5303/2