Renewing radial sealing ring of power steering pump
WIS 46-705
Note: These repair instructions apply only to models 107, 123 and 126.
Oil types/filling capacities and oil level checkup
ATF (automatic transmission fluid) refer to specifications for Page 236.2 or manual transmission oil service products refer to specifications for Page 237 service products
107, 123 1.4 Filling capacity approx. liters 126 1.2
Oil level checkup: With oi! at operating temperature (approx. 80 °C) the oil level in supply tank should reach up to punched-in or cast-in mark (approx. 20 mm below edge of tank). With cold oil and at ambient temperature oil level should be 6–8 mm below mark. Use only perfectly clean oil for refilling, since already minimum particles of dirt may lead to trouble in hydraulic system.
Tightening torques
Nm
High-pressure expanding hose to power steering pump 45–50
Connecting pipe for return flow hose 45–50
Special tools
Puller for pulley – 108 589 02 33 00
Puller for radial sealing ring (baisc unit) – 116 589 24 33 00
| Claw 33 mm dia. for Vickers VT 27, ZF and Vickers VT 49 2nd version PERE Claw 30 mm dia. for Vickers VT 49 Ist version | 11004-6306 |
| Installation mandrel 33 mm dia. for Vickers VT 27, ZF and Vickers VT 49 2nd version Installation mandrel 30 mm dia. for Vickers VT 49 1st version | PEE > 11006-6305 |
Removal
1. Remove power steering pump.
2 Remove Woodruff key on drive shaft.
3 On Vickers power steering pump VT 49 measure outlet end dimension of drive shaft in relation to pump flange.
Note: The dimension of drive shaft must be obtained because the drive shaft must not be forced into pump housing when pulling off the radial sealing ring. To check, measure again after removing sealing ring. Note that both measured values must be the same. If the dimension is larger during 2nd measurement, disassemble power steering pump and recondition.
4 Screw guide sleeve (050) on drive shaft.
146-1014!
5 Screw back hex. screw of puller (050) and slip device on drive shaft, while punching with claws (051) through sealing lips of radial sealing ring (13).
Note: For power steering pumps, the puller requires the following claws: Vickers VT 27, ZF, Vickers VT 49 2nd version = 33 mm dia. Vickers VT 49 1st version = 30 mm dia.
The respective claws must be attached to puller. The claw diameter is punched in.
46,.7-705/2 F2
6 Turn clamping cone (arrow) of puller (050) up to stop in clockwise direction and pull sealing ring out of case.
7 On Vickers power steering pump VT 49, measure axial play of drive shaft (refer to note following item 3).
Installation
8 Slip radial sealing ring (13) over guide sleeve (050) on drive shaft and knock into case by means of respective installation mandrel (053).
Note: For Vickers power steering pump VT 27, ZF and Vickers VT 49 2nd version the installation mandrel with 33 mm dia. will be required, and for VT 49 pump 1st version the installation mandre! with 30 mm dia.
9 Insert Woodruff key into drive shaft. 146-10 144
10 Install power steering pump.