Checking lower control arm
WIS 33-570
Checking dimension
Distance ‘a’ (front edge bearing eye – outer threaded bore for suspending shock absorber)
148.6 + 4
| Conventional tool Height measuring and marking instrument size II|, measuring range up to 500 mm | e.g. made by Stiefelmayer, D-7300 Esslingen order no. 151 AR | |
| Self-made tool | a —_ | |
| Hex bolt with center point | ||
| Checkup | ||
1 Remove bearing of control arm (33—520).
2 Clamp control arm on surface plate at bore for bearing by means of a srew clamp.
3 Screw measuring screw into outer bore for shock absorber suspension.
4 Measure distance ‘‘a’’ between surface plate and center of center bore in measuring screw. If the specified dimension is above or below specified distance, replace control arm.