Testing fuel gauge
WIS 54-257
Test values immersion tube transmitter in ohms
Model Resistance, readout full Resistance, readout reserve
Sedan, coupe 1.6+0.7 56.9+1.9 T-sedan 3.2+0.8 62.2 42.1
Testing immersion tube transmitter (removed)
Connect ohmmeter to terminal G and terminal 31 and measure resistance.
a) In installation position (readout reserve, float below).
b) Rotated by 180° (readout full, float at top).
Testing reserve warning contact
Connect ohmmeter to terminal W and terminal 31 and measure resistance.
a) Nominal value 0 ohm in installation position.
b) Nominal value co ohm turned by 180°,
Testing harness
1 Pull coupler from immersion tube transmitter and © CO Oo measure resistance on jack 3 and vehicle ground.
4 3 © Oo= Nominal value 0 ohm J
(At test value 2° ohm the grounding line is interrupted). we 1544-7831/1
§4.3-257/1
on installed immersion tube transmitter. Value depends on amount of fuel in tank. Plug coupler back on immersion tube transmitter.
3 Pull coupler from instrument cluster and measure resistance between jack 3 and jack 15.
Nominal value sedan and coupe: the value measured under 2. If the value is attained, the harness is in order (slight deviation caused by length of line possible).
Nominal value T-sedan and special vehicles: the value measured under 2 plus 4.7 ohm. If the value is attained, the harness is in order (slight deviation caused by length of line possible).
4 If the measured value is higher or at %° ohm, the harness couplers (on instrument cluster, on main harness/tail harness or on immersion tube transmitter} are having poor contact, a dry joint or a line is interrupted.
5 If no fault is found during tests, exchange indicating instrument.