Renewing bulbs of control system, heater

WIS 54-390

Removal

Renewing bulbs of control system, heater – rysunek

1 Pull off knobs of heater regulation left (1) and right (2), as well as of blower switch (3). (Knobs are mounted conically).

The bulbs of the switches can now be pulled out of socket.

Renewing bulbs of control system, heater – rysunek

1st version

2nd version

Renewing bulbs of control system, heater – rysunek

2 Remove cover of operating system (5) by unscrewing nuts (6) and pulling off knob of air flap (7).

Renewing bulbs of control system, heater – rysunek

3 Pull sockets (1) out of cover (2).

Installation

4 For installation proceed vice versa.

When inserting bulb, make sure that the contact springs of the switches or sockets are not distorted.