Checking single diaphragm, double diaphragm and piston vacuum pump

WIS 43-660

Data

The suction time is measured in seconds up to 0.5 bar vacuum at an engine speed of 750/min. The following data apply:

Brake booster and Brake unit and comfort circuit Brake unit vented (comfort circuit (e.g. central locking system) vented in order and suction completed) vacuum pump

9” and 10” single diaphragm brake booster and single 15 — 18 10 — 13 diaphragm vacuum pump

9” double diaphragm brake 25 — 26 17 — 18 booster and single diaphragm vacuum pump

9″ double diaphragm brake booster and double 18 — 19 12 —13 diaphragm vacuum pump

9° double diaphragm brake 13— 14 9–11 booster and piston vacuum pump 2–13 7–9 10” single diaphragm brake booster and piston vacuum pump

With the engine stopped, a vacuum drop of 0.2 bar within 30 seconds is permitted.

Checking single diaphragm, double diaphragm and piston vacuum pump – rysunek

Special tool

Vacuum tester – 116 589 25 21 00

Self-made tool

Measuring connection refer to fig. item 1, note

Checking single diaphragm, double diaphragm and piston vacuum pump – rysunek

Testing

1 Connect tester (030) with measuring connection (020) to vacuum line (8) between check valve and brake booster (1).

Checking single diaphragm, double diaphragm and piston vacuum pump – rysunek

Note: The measuring connection is self-made according to specified dimensions (parts 1, 3, 4, 5 and 6 are brazed to each other). For connection to brake booster the pipe section and coupling nut of an old vacuum line may be used. Connection to vacuum line is made by means of a screw connection.

2 Run engine at 750/min and measure the time until a vacuum of 0.5 bar has been established.

Note: if the specified data are not attained or if the vacuum drop is more than 0.2 bar in 30 s, check vacuum system for leaks. If no fault is found, recondition vacuum pump or renew.