Checking the actuator

WIS 54-505

A. Electrical checkup

Test data

Line-up on plug of actuatorapprox. nominal value in Ohms
1 2. 4 5 5(pink/yellow) (pink/yellow) (brown/green) (yellow/red) (yellow/red)2 (gray/black) 3 (white/pink) 6 (violet/blue) 6 (violet/blue) with adjusting lever extended 6 (violet/blue) with adjusting lever retracted50 000 24 000 14 00085 85
Checking the actuator – rysunek

1 Disconnect cable control on actuator.

2 Disconnect white plug connection between actuator and line harness.

3 Test resistances of actuator on white plug with Ohmmeter, check line-up 5—6 with adjusting lever extended and retracted manually (refer to test data).

4 If the test data are not attained or exceeded, replace actuator.

B. Function test

5 Start engine. Connect line-up 1 (pink/yellow) on plug of actuator to battery +, and line-up 3 (white/ pink) to battery —.

6 Then connect line-up 2 (gray/black) of plug to battery —, the adjusting lever of actuator is retracted and should remain in its position or move slowly out again.

7 Loosen line-up 2 (gray/black) from battery —, the adjusting lever of the actuator should immediately move out again.

8 Replace actuator, if required.